372 Chapter 15
W-CDMA Uplink Digital Modulation for Receiver Test
Generating a Single PRACH Signal
2. Press LF Out Waveform > More (1 of 2) > Pulse.
3. Press
LF Out Period > 21 > msec.
4. Press
LF Out Width > 1 > msec.
5. Press
LF Out Amplitude > 5 > Vp.
6. Press
LF Out Off On to On.
Viewing the PRACH Message Using an AICH Trigger
This procedure guides you through configuring the PSA for making a spectrum analysis
measurement. This is being done to familiarize you with the different measurement modes
that exist for the PSA. You could use the W-CDMA mode, time domain measurement, to
achieve the same results.
1. Preset the signal analyzer.
2. Select the spectrum analysis mode.
Press
Mode > Spectrum Analysis.
3. Set the center frequency to 1.95 GHz.
Press
Center Freq > 1.95 > GHz.
4. Set the span to zero hertz for close-in viewing of the PRACH signal.
Press
Span > 0 > Hz.
5. Set the sweep time to 50 ms.
Press
Sweep > Sweep Time > 50 > ms.
6. Set the signal analyzer to trigger from the ESG’s PRACH pulse trigger signal.
Press
Trig > Ext Rear.
You now see the message part moving across the display as the AICH trigger is received after
each preamble. Figure 15-18 shows the message part as it appears after the third preamble
transmission.