282 Chapter 12
Real Time TDMA Formats
DECT Framed Modulation
DECT Framed Modulation
This example teaches you how to build framed real-time I/Q baseband generated DECT
modulation for testing receiver designs. The procedures in this section build on each other and
are designed to be used sequentially.
Activating Framed Data Format
1. Press Preset.
2. Press
Mode > Real Time TDMA > More (1 of 2) > DECT > Data Format Pattern Framed.
Configuring the First Timeslot
1. Press Configure Timeslots > Timeslot Type > Custom.
2. Press
Configure Custom > Other Patterns > 8 1’s & 8 0’s.
Configuring the Second Timeslot
1. Press Timeslot # > 1 > Enter.
2. Press
Timeslot Type > Traffic Bearer.
3. Press
Configure Traffic Bearer > B field > Other Patterns > 4 1’s & 4 0’s.
4. Press
Return > Timeslot Off On to On > Return.
Generating the Baseband Signal. Press DECT Off On to On.
This generates a DECT signal with an active custom timeslot (#0) and an active traffic bearer
timeslot (#1). The signal generator may require several seconds to build the signal. During
this time, Baseband Reconfiguring appears on the display. After the reconfiguration is
complete, the display reads DECT On and the DECT, ENVLP, and I/Q annunciators appear. The
signal is now modulating the RF carrier.
The signal’s configuration data resides in volatile memory and is not recoverable after an
instrument preset, power cycle, or reconfigured signal generation.
Configuring the RF Output
1. Set the RF output frequency to 1.89 GHz.