226 Chapter 8
CDMA Digital Modulation
cdma2000 Forward Link Modulation for Receiver Test
Figure 8-10 Forward Fundamental Channel (F-FCH) Setup
Note that the ESG allows you to set the relative channel power for each active channel. To
display the normalized relative channel power after completing the setup, it is recommended
that you perform the steps in “Adjusting Code Domain Power” on page 226. Also note that
varying the EbNo value on one channel will affect the EbNo values on all active channels.
Refer to “Managing Noise” on page 227 to learn how to make final noise adjustments.
Adjusting Code Domain Power
The tasks in this procedure build upon the previous procedure. This procedure teaches you
how to perform the following tasks:
• “Scaling to 0 dB” on page 226
• “Setting Equal Channel Powers” on page 227
Scaling to 0 dB
After changing the relative power level for a channel, the ESG automatically scales the total
power to 0 dB, while preserving the relative channel power levels. The displayed power levels
remain unchanged so the user can complete the relative power adjustments. This task teaches
you how to update the display to show the normalized relative channel power for each channel
after completing the setup.
1. Press
Mode Setup to return to the top-level real-time cdma2000 menu.
2. Press
Link Control > Adjust Code Domain Power > Scale to 0 dB.