234 Chapter 8
CDMA Digital Modulation
cdma2000 Reverse Link Modulation for Receiver Test
Figure 8-15
Managing Noise
The tasks in this procedure build upon the previous procedure.
The following tasks teach you how to set the overall carrier-to-noise (C/N) ratio for the reverse
link cdma2000 setup and to set the EbNo value for individual physical channels.
“Setting the Carrier to Noise Ratio” on page 234
“Setting EbNo” on page 234
Setting the Carrier to Noise Ratio
1. Press
Mode Setup to return to the top-level real-time cdma2000 menu.
2. Press
Noise Setup > C/N > 10 > dB.
3. Press
Noise Off On to On.
You have now set the overall carrier to noise ratio to 10 dB and turned on noise. This is done
to apply a discernible level of noise across the entire channel space.
Setting EbNo
EbNo can be set in the Noise Setup menu or the Channel Setup table editor (see “Modifying
Channel Parameters” on page 231). This task teaches you how to make quick EbNo
adjustments using the
EbNo softkey in the Noise Setup menu.
1. Press Channel Number and move the cursor to highlight the reverse fundamental channel
(R-FCH).
2. Press EbNo > 20 > dB.
You have now set the EbNo value for the R-FCH channel to 20 dB. Note that modifying the
EbNo value for a channel will change the overall carrier to noise ratio and the EbNo value for
all other active channels. For reliable results when making hand calculations to determine or
verify EbNo values, it is recommended that you first scale the code domain power to 0 dB to
display the normalized relative channel power levels (see “Scaling to 0 dB” on page 232).
Displayed Power Levels
After Equal Powers
Seitenansicht 249