154 Chapter 4
Analog Modulation
Configuring Pulse Modulation
Configuring Pulse Modulation
Using the following procedures, you will learn how to create a pulse-modulated RF carrier.
Setting the RF Output Frequency
1. Press Preset.
2. Press
Frequency > 2 > GHz.
Setting the RF Output Amplitude
Press Amplitude > 0 > dBm.
Setting the Pulse Period and Width
1. Press Pulse > Pulse Period > 100 > usec.
2. Press
Pulse > Pulse Width > 24 > usec.
The signal generator is now configured to output a 0 dBm, pulse-modulated carrier at 2 GHz
with a 100-microsecond pulse period and 24-microsecond pulse width. The pulse source is set
to Internal Pulse. (Notice that Internal Pulse is the default for the
Pulse Source softkey.)
Activating Pulse Modulation
Follow these remaining steps to output the pulse-modulated signal.
1. Press
Pulse Off On to On.
2. Press
RF On/Off.
The Pulse and RF ON annunciators are now displayed. This indicates that you have enabled
pulse modulation and the signal is now being transmitted from the RF OUTPUT connector.