Agilent Technologies B1500A Betriebsanweisung Seite 144

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 628
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 143
3- 14 Agilent B1500 User’s Guide, Edition 7
Installation
Installing Accessories
To Connect Connector Plate
The available connector plates are listed in Table 3-2. Option 001 provides the
through connectors except for the Interlock connector that prov
ides the soldering
patterns at the back side. For the option 002, the back of each connector is designed
for soldering. For connector plate installation information, refer to Agilent 16495
Installation Guide.
For the 16495H/J, the insulator is inserted between the panel and the outer
conductor of Tr
iax connectors/BNC connectors.
Use the cables shown in Table 3-3 to connect from the B150
0A connectors to the
connector plate’s relative connectors. For the cable connections from th
e connector
plate to the DUT interface such as manipulator and probe card, see “Mounting
Connectors” on page 3-27 as reference.
NOTE Making non-Kelvin connection
The Force terminals can be used to force and measure DC voltage or current. If you
want to simplify the cable connections, open the Sense terminals and connect the
Force terminals only to the connector plate by using the triaxial cables.
If you make the Kelvin connection, use both Force and Sense terminals. Connecting
the Force and Sense
lines together at the terminal of the device under test minimizes
the measurement error caused by the residual resistance of the connection cables.
The Kelvin connection is effective for the low resistance measurement and the high
current measurement.
Table 3-2 Connector Plates
Model Option Item Connectors
16495F 16495F-001 Triax. (f-f) ×12, GNDU (f-f)
×1, Interlock (f) ×1
16495F-002 Triax. (f) ×12, GNDU (f) ×1, Interlock
(f) ×1
16495G 16495G-001 Triax. (f-f) ×24, GNDU (f-f)
×1, Interlock (f) ×1
16495G-002 Triax. (f) ×24, GNDU (f) ×1, Interlock
(f) ×1
16495H 16495H-001 Triax. (f-f) ×6, Coax. (f-f) ×6, GNDU (
f-f) ×1, Interlock (f) ×1
16495H-002 Triax. (f) ×6, Coax. (f) ×6, GNDU (f)
×1, Interlock (f) ×1
16495J 16495J-001 Triax. (f-f) ×8, Coax. (f-f) ×4, GNDU (
f-f) ×1, Interlock (f) ×1
16495J-002 Triax. (f) ×8, Coax. (f) ×4, GNDU (f)
×1, Interlock (f) ×1
16495K 16495K-001 Connector plate, rubber holder
Seitenansicht 143