DisplayPort Test Implementation Group 19 Agilent J-BERT N4903B & 90000A/X/Q Series Sink Draft2
Tables 4-3 and 4-4 of the CTS. The error term is divided by the HF jitter amplitude to
account for effect of the equalization and jitter transfer function at TP3_EQ.
a. For HBR and HBR2, Calculate the required SJ
SWEEP
target value based on the equation above
using the measured values from9.1, 9.2 and 9.3.1.
Figure 13: Table 4-3 and 4-4 from the PHY CTS 1.2b
For this example, the target value for SJ
SWEEP
is calculated as follows:
SJ
SWEEP (2MHz)
= 505 * (1 + (.520 (220+197+101))/100) = 505 * 1.02= 515
SJ
SWEEP (10MHz)
= 116 * (1 + (.520 (220+197+101))/100) = 116 * 1.02= 118
SJ
SWEEP (20MHz)
= 104 * (1 + (.520 ((220+197+101)))/100) = 104 * 1.02= 106
SJ
SWEEP (100MHz)
= 110 * (1 + (.520 ((220+197+101)))/100) = 110 * 1.02 = 112
b. In the J-BERT N4903B Jitter Setup menu, disable all Jitter terms accept PJ 2.
c. Set the frequency for PJ 2 to 10 MHz.
d. Alternate between adjusting the PJ 2 on J-BERT N4903B user interface and pressing the
Single Acquisition Button on the Oscilloscope until the PJ
(d-d)
is calibrated to the following
values.
For RBR
For HBR
For HBR2
Correction factor for SJ
SWEEP
does not apply. Use the equation
below to arrive at the target
value for PJ 2.
Adjust PJ 2 to the new target
value based on the calculations
made above.
Adjust PJ 2 to the new target
value based on the calculations
made above.