Seite 1 - Link Training Suite

Agilent Technologies N5990A-301PCI ExpressLink Training SuiteGetting Started Guide

Seite 2

5. Using the SoftwareConnecting To The InstrumentsOnce the software started, the main window and the connection dialog will appear as shown in Figure

Seite 3 - Find a Mistake?

8. Click the „Connect“ button9. If the connection was successful, the button „Apply and Close“ will be enabled, see Figure 410. Click the „Apply and C

Seite 4 - Contents

Main User InterfaceAfter the successful connection to the instruments, the main window is displayed as given in Figure 5. This window is split into tw

Seite 5

HelpIn the “Help” menu (top right corner of the main window), you will find:• The "Getting Started Guide" (F1; this document)• The "Lan

Seite 6 - 1. Introduction

Demo ModeWhen you close the connection dialog without connecting instruments, you enter the Demo Mode.The Demo Mode is intended for demostration purpo

Seite 7 - Software Installation

When the de-emphasis signal converter is connected, or when the PCIExpress specification 3.0 is used, the current preset is also shown. The “Preset...

Seite 8 - Software Registration

All other parameters reflect the standard sequence described in the CTS. Note that “Min. initial TS1 count” and “Min TS1 count before Loopback” are on

Seite 9 - 4. Setup

In the simplest case, a custom pattern file can be a text-file containing only hexadecimal data. Note that the binary data represented by this file mu

Seite 10 - 5. Using the Software

Error DetectorBy default, the J-BERT error detector compares all bits from the DUTwith the loopback pattern. With the option in the “Error Detector” g

Seite 11

By default, the generator uses an internal clock source, or an external clock multiplier (N4880A) for system board tests. Note that the N4880A must be

Seite 12 - Main User Interface

Notices© Agilent Technologies, Inc. 2013No part of this manual may be reproduced in any form or by any means (including electronic storage and retriev

Seite 13

Note that some jitter/SSC parameters will reset the sequencer when modified. This means that the current sequencer state is left and the link training

Seite 14 - Applying

When the “Poll Sequence State” option in the “Options” menu is enabled, the current state of the sequencer is shown.When the sequence contains a loop

Seite 15 - Link Training Pattern

Saving And Loading SettingsYou can store your current settings using the “Apply and Save...” button in the main window, or via the main menu. Note tha

Seite 16 - Loopback Pattern

When the radio button “Generate From Parameters” is checked, the pattern will be automatically generated, i. e. the same way as in non-Expert Mode. Wh

Seite 17 - Clock Tolerance Compensation

To edit the script, click the “Edit Script” button. The script editor, as shown in Figure 19, will pop up. In the script editor, you can edit the sequ

Seite 18 - Output Parameters

6. TroubleshootingStartup FailsThe anti-virus software Sophos Endpoint Security might inadvertendly detect the PCIe Link Training Suite as a virus and

Seite 19 - Jitter/SSC

7. Switching to Version 1.1ScriptThe PCIe Link Training Suite v1.0 automatically inserted a pause at the beginning of the link training sequence. You

Seite 20 - Sequencer

8. SupportIn case of persisting problems with the PCI Express Link Training Suite, please send a problem description to the PCI Express support node p

Seite 21 - Power Switching

Technical Assistance: Contact CenterIf you need product assistance or if you have suggestions, contact theAgilent Technologies, Inc. Contact Center in

Seite 22 - Script Editing

Contents1. INTRODUCTION...6PCI Express Link Tr

Seite 23

Startup Fails...

Seite 24 - Limitations

1. IntroductionPCI Express Link Training SuiteThe Agilent PCI Express Link Training Suite (N5990A-301) is a software tool which allows to train PCI Ex

Seite 25 - 6. Troubleshooting

2. Software Installation and UpdateThe PCI Express Link Training Suite N5990A-301 runs on a PC whichcontrols the J-BERT. If N5990A-301 is already inst

Seite 26 - 7. Switching to Version 1.1

3. Starting and Registering the SoftwareStarting Registered SoftwareDouble click on the PCI Express Link Training Suite icon on the desktop or start t

Seite 27 - 8. Support

4. SetupThere are several instruments which can be controlled by the PCIe Link Training Suite when properly connected:• An N4903B J-BERT is required◦