Programming Guide 1-57
ESG Family Signal Generators Preparing for Use
Programming the Status Register System
Figure 1-28.
The Data Questionable Status Group also contains a Data Questionable Event Enable
Register. This register lets you choose which bits in the Data Questionable Event Register
will set the summary bit (bit 3 of the Status Byte Register) to 1. Send the
STATus:QUEStionable:ENABle <num> command where <num> is the sum of the decimal
values of the bits you want to enable. For example, to enable bit 9 and bit 3 so that
whenever either of those bits is set to 1, the Data Questionable Status summary bit of the
Status Byte Register will be set to 1, send the command STAT:QUES:ENAB 520 (512 + 8).
The command STATus:QUEStionable:ENABle? returns the decimal value of the sum of
the bits previously enabled with the STATus:QUEStionable:ENABle <num> command.