Agilent Technologies E8267D PSG Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Stromgeneratoren Agilent Technologies E8267D PSG herunter. Agilent E8267D PSG Vector Signal Generator Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Agilent E8267D PSG
Vector Signal Generator
Data Sheet
The Agilent E8267D is a fully synthesized signal generator with high output power, low phase
noise, and I/Q modulation capability.
Specifications apply over a 0 to 55 °C range, unless otherwise stated, and apply after a
45 minute warm-up time. With vector modulation on, specifications apply after executing
I/Q calibration with the instrument maintained within ±5 °C of the calibration temperature
unless otherwise stated. Supplemental characteristics, denoted as typical, nominal, or mea-
sured, provide additional (non-warranted) information at 25 °C, which may be useful in the
application of the product.
Unless otherwise noted, this data sheet applies to units with serial numbers ending with
50420000 or greater.
Definitions
Specifications (spec): Represents warranted performance for instruments with a current
calibration.
Typical (typ): Represents characteristic performance which is non-warranted. Describes
performance that will be met by a minimum of 80% of all products.
Nominal (nom): Represents characteristic performance which is non-warranted.
Represents the value of a parameter that is most likely to occur; the expected mean or
mode of all instruments at room temperature (approximately 25 °C).
Measured: Represents characteristic performance which is non-warranted. Represents the
value of a parameter measured on an instrument during design verification.
Seitenansicht 0
1 2 3 4 5 6 ... 33 34

Inhaltsverzeichnis

Seite 1 - Vector Signal Generator

Agilent E8267D PSG Vector Signal GeneratorData SheetThe Agilent E8267D is a fully synthesized signal generator with high output power, low phase noise

Seite 2 - Table of Contents

1. Sub-harmonics are defined as carrier freq * (x/y), where x and y are integers, and x is not an integer multiple of y. Specifications are typical for

Seite 3 - Specifications

Option UNX carrier frequency SONET/SDH data rates RMS jitter bandwidth Unit intervals (μUI) Time (fs)155 MHz 155 MB/s 100 Hz to 1.5 MHz 23 151622 MHz

Seite 4 - Step (digital) sweep

Option UNX: absolute SSB phase noise (dBc/Hz) (CW) 1, 2Offset from carrierFrequency 1 Hz spec (typ)10 Hz spec (typ)100 Hz spec (typ)1 kHz spec (typ)

Seite 5

1. I/Q modulator attenuator set to auto. External I/Q input level √(I 2 + Q 2) = 0.5 Vrms. L(f) (dBc/Hz) vs. f (Hz)Standard absolute SSB phase noise

Seite 6 - Frequency (GHz)

L(f) (dBc/Hz) vs. f (Hz)AM noise (measured)-20-30-40-50-60-70-80-90-100-110-120-130-140-150-160-1701 10 100 1 k 10 k 100 k 1 M 10 M 100 M44 GH

Seite 7 - Level accuracy (measured)

1. Through any combination of path1, path2, or path1 + path2.2. Specifications apply in CW and list/step sweep modes. During ramp sweep operation (Op

Seite 8 - RF output limit (measured)

Phase modulation (Option UNT)Maximum deviation 1Standard or Option UNX Frequency 100 kHz BW mode 1 MHz BW mode250 kHz to 250 MHz 20 rad 2 rad> 250

Seite 9 - Spectral purity

Amplitude modulation 1 (Option UNT) (typical)Depth Linear mode Exponential (log) mode (downward modulation only)MaximumALC on > 90% > 20 dBALC o

Seite 10

1. With ALC off, specs apply after the execution of power search. Specifications apply with Atten Hold Off (default mode for instruments with attenuat

Seite 11 - Frequency Spec Typical

Measured pulse modulation envelopeFrequency = 9 GHz, amplitude = 10 dBm, ALC off, 10 ns/divInternal pulse generator (Option UNU or UNW)Modes Free-run

Seite 12 - Frequency 1 Hz

Table of ContentsSpecifications ... 3 Fr

Seite 13 - ) = 0.5 V

Carrier at 900 MHz (measured)6420-2-4-6-8-10Relative gain (dB)Offset from carrier (MHz)-200 -150 -100 -50 0 50 100 150 200Carrier at 2.4 GHz (

Seite 14 - Standard

I/Q adjustmentsI & Q offsets External inputs (600 Ω): ±5 VoltsExternal inputs (50 Ω): ±50%Internal baseband generator: ±50%I/Q attenuation 0 to 40

Seite 15

2.000.00–2.00–4.00–6.00–8.00–10.00Relative gain (dB)Carrier at 10 GHz (measured)Offset from carrier (MHz)–1000–800 –600 –400 200 0 200 400 600 800 100

Seite 16 - Phase modulation (Option UNT)

RF path filters 1Carrier frequency Nominal filter cutoff frequencies> 3.2 to 5 GHz 5.5 GHz low-pass filter> 5 to 8 GHz 8.9 GHz low-pass filter>

Seite 17 - (Option UNT) (typical)

ClockSample rate 1 Hz to 100 MHzResolution 0.001 HzAccuracy Same as timebase +2–42 [in non-integer applications]Reconstruction filter: [fixed] 50 MHz

Seite 18 - (Option UNU or UNW)

44 GHz image rejection (measured)44 GHz multitone (measured)Ref-10 dBmSampLog10dB/LgAv10W1 S2S3 FC £(f):FTunSwp◊Atten 2 dB ∆ Mkr1 -9.00 MHz-53.585

Seite 19 - Simultaneous modulation

44 GHz two-tone (measured)20 GHz two-tone (measured)Ref-4 dBmSampLog10dB/LgAv10W1 S2S3 FC (f):#f>50K#Swp#Atten 6 dBMkr1 -20.00 MHz-62.275 dBCent

Seite 20 - (Standard I/Q inputs)

FIR filterSelectable Nyquist, root Nyquist, Gaussian, rectangular, α: 0 to 1, BbT: 0.1 to 1Custom FIR 16-bit resolution, up to 64 symbols long, automa

Seite 21 - (Option 016)

Spectral re-growth (measured)Ref-12 dBmSampLog10dB/LgAv100W1 S2S3 FC £(f):FTunSwp◊Atten 10 dB ∆ Mkr1 12.00 MHz-64.622 dBCenter 10.000 00 GHz◊Res B

Seite 22 - Offset from carrier (MHz)

1. During storage below -20 °C, instrument states may be lost.2. As is the case with all signal generation equipment, phase noise specifications are

Seite 23

SpecificationsFrequencyRange Specified range Tunable rangeOption 520 250 kHz to 20 GHz 100 kHz to 20 GHzOption 532 250 kHz to 31.8 GHz 100 kHz to 31.8

Seite 24

Front panel connectors (All connectors are BNC female unless otherwise noted.) 1RF output Output impedance 50 Ω (nom)Option 520 Precision APC-3.5 male

Seite 25 - 44 GHz multitone (measured)

Rear panel connectors (all connectors are BNC female unless otherwise noted) 1Auxiliary interface (dual mode) Used for RS-232 serial communication and

Seite 26 - 20 GHz two-tone (measured)

Model/option DescriptionE8267D-520 Frequency range from 250 kHz to 20 GHzE8267D-532 Frequency range from 250 kHz to 31.8 GHzE8267D-544 Frequency range

Seite 27 - EVM (measured)

E8267D-UNY Enhanced ultra low phase noiseE8267D-UNT AM, FM, phase modulation, and LF outputE8267D-UNU Pulse modulationE8267D-UNW Narrow pulse modulati

Seite 28 - Remote programming

Web ResourcesRelated Agilent LiteratureFor additional product information, visit:www.agilent.com/find/psgFor information about renting, leasing or fin

Seite 29 - General specifications

External referenceFrequency 10 MHz onlyLock range ±1.0 ppmReference outputFrequency 10 MHzAmplitude > +4 dBm into 50 Ω load (typ)External reference

Seite 30 - Input/Output Descriptions

Ramp (analog) sweep (Option 007) 1Operating modes• Synthesized frequency sweep (start/stop), (center/span), (swept CW)• Power (amplitude) sweep (sta

Seite 31

OutputMinimum settable output power –130 dBmMaximum output power (dBm) 1Spec (Typ)Frequency range 2CW Standard I/Q 3Wideband I/Q 4Option 52010 to 250

Seite 32 - Model/option Description

1. The step attenuator provides coarse power attenuation to achieve low power levels. Fine power level adjustment is provided by the ALC (automatic l

Seite 33

Adjustable RF output limitFrequency [GHz]222028Power [dBm]01816142624510152025 dBm20 dBm23 dBm15 dBmRF output limit (measured)Resolution 0.01 dBTemper

Seite 34 - Literature

1. Specifications are typical for harmonics beyond specified frequency. Specifications are with Option 1EH low-pass filters below 2 GHz off, unless n