2-56 Programming Guide
Programming Commands and Examples ESG Family Signal Generators
:PULM Subsystem
:PULM Subsystem
The pulse modulation subsystem is used to set the modulation controls and the parameters
associated with pulse modulated signals.
Fast Pulse Modulation State
:PULM:FAST:STATe ON|OFF|1|0
:PULM:FAST:STATe?
This command sets the operating state of fast pulse modulation. The choices are On (1) or
Off (0).
*RST Value: Off
Internal Pulse Modulation Pulse Period Configuration
:PULM:INTernal[1]:PERiod <val><unit>
:PULM:INTernal[1]:PERiod?
This command sets the period time for the internally-generated pulse modulation source.
The choices for the variables <val> and <unit> range from 30 seconds to 16 microseconds.
*RST Value: 80.0
µsec
Internal Pulse Modulation Pulse Width Configuration
:PULM:INTernal[1]:PWIDth <val><unit>
:PULM:INTernal[1]:PWIDth?
This command sets the pulse width for the internally-generated pulse modulation source.
The choices for the variables <val> and <unit> range from 8.0 microseconds to the value
of the pulse period.
*RST Value: 40.0
µsec