92 Chapter 5 Setting Measurement ConditionsSetting Sweep RangeFigure 5-7 After MKR ® CENTERFigure 5-8

Seite 4

Chapter 5 93Setting Measurement ConditionsSetting Sweep Range5. Setting MeasurementConditionsFigure 5-9

Seite 5

94 Chapter 5 Setting Measurement ConditionsUsing Time as Sweep Parameter (Zero Span Sweep)Using Time as Sweep Parameter (Zero Span Sweep) Setting the

Seite 6

Chapter 5 95Setting Measurement ConditionsUsing Time as Sweep Parameter (Zero Span Sweep)5. Setting MeasurementConditions[Utility] - MKR X-AXIS [ ] -

Seite 7

96 Chapter 5 Setting Measurement ConditionsUsing Time as Sweep Parameter (Zero Span Sweep)Figure 5-11 Sweep span value = 0 Hz (zero span sweep)

Seite 8

Chapter 5 97Setting Measurement ConditionsSetting Number of Points (NOP)5. Setting MeasurementConditionsSetting Number of Points (NOP)Step 1. Press [S

Seite 9 - Operation Manual

98 Chapter 5 Setting Measurement ConditionsSetting Number of Points (NOP)Figure 5-13 Number of points: 801

Seite 10 - Manual Printing History

Chapter 5 99Setting Measurement ConditionsSelecting Sweep Direction5. Setting MeasurementConditionsSelecting Sweep DirectionDUT can be measured in the

Seite 11 - Safety Summary

100 Chapter 5 Setting Measurement ConditionsManual Sweep (Measurement at a Specified Point)Manual Sweep (Measurement at a Specified Point) In the norm

Seite 12 - Safety Symbols

Chapter 5 101Setting Measurement ConditionsManual Sweep (Measurement at a Specified Point)5. Setting MeasurementConditionsFigure 5-14 Manual Sweep

Seite 13 - Limitation of Warranty

3Safety SummaryThe following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Fai

Seite 14 - Typeface Conventions

102 Chapter 5 Setting Measurement ConditionsSetting Time Delay for MeasurementSetting Time Delay for MeasurementTime delay can be set for the period b

Seite 15 - 4294A and how to

Chapter 5 103Setting Measurement ConditionsSetting Time Delay for Measurement5. Setting MeasurementConditionsSetting with sweep time delayTime delay c

Seite 16

104 Chapter 5 Setting Measurement ConditionsSetting Fixed Frequency (CW Frequency)Setting Fixed Frequency (CW Frequency)Follow the steps below to spec

Seite 17 - Contents

Chapter 5 105Setting Measurement ConditionsSetting Oscillator Level5. Setting MeasurementConditionsSetting Oscillator LevelFollow the steps below to s

Seite 18

106 Chapter 5 Setting Measurement ConditionsSelecting Unit for Oscillator Level (Voltage or Current)Selecting Unit for Oscillator Level (Voltage or Cu

Seite 19

Chapter 5 107Setting Measurement ConditionsSetting and Applying dc Bias5. Setting MeasurementConditionsSetting and Applying dc BiasFollow the steps be

Seite 20

108 Chapter 5 Setting Measurement ConditionsSetting and Applying dc Bias• Enter the desired value with the numeric keys ([0] to [9], [.], and [-]) and

Seite 21

Chapter 5 109Setting Measurement ConditionsSetting and Applying dc Bias5. Setting MeasurementConditionsrange as narrow as possible without causing the

Seite 22

110 Chapter 5 Setting Measurement ConditionsSetting and Applying dc Biasselected is displayed in the key label [] of the MEAS RANGE [ ] key.NOTE If th

Seite 23

Chapter 5 111Setting Measurement ConditionsSelecting a Method to Start Measurement (Trigger Source)5. Setting MeasurementConditionsSelecting a Method

Seite 24

4 Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must

Seite 25 - 1 Installation

112 Chapter 5 Setting Measurement ConditionsSelecting Sweep Trigger/Measurement Point TriggerSelecting Sweep Trigger/Measurement Point TriggerYou can

Seite 26 - Incoming Inspection

Chapter 5 113Setting Measurement ConditionsSelecting Polarity of External Trigger Input Signal5. Setting MeasurementConditionsSelecting Polarity of Ex

Seite 27

114 Chapter 5 Setting Measurement ConditionsSpecifying Sweep Times and Stopping SweepSpecifying Sweep Times and Stopping SweepYou can specify the numb

Seite 28 - Power Source Requirements

Chapter 5 115Setting Measurement ConditionsSpecifying Sweep Times and Stopping Sweep5. Setting MeasurementConditionsstopping (hold) state. No further

Seite 29 - Power Cable

116 Chapter 5 Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a Single Action (List Sweep)Sweeping Multiple

Seite 30 - Installation

Chapter 5 117Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a SingleAction (List Sweep)5. Setting Measureme

Seite 31

118 Chapter 5 Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a Single Action (List Sweep)Figure 5-17 Prepar

Seite 32 - Using the LAN Port

Chapter 5 119Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a SingleAction (List Sweep)5. Setting Measureme

Seite 33 - Connecting the Keyboard

120 Chapter 5 Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a Single Action (List Sweep)The above setting

Seite 34 - Using a Rackmount Kit

Chapter 5 121Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a SingleAction (List Sweep)5. Setting Measureme

Seite 35 - Option 1CM Rackmount Kit

5CertificationAgilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent Te

Seite 36 - Instructions for Cleaning

122 Chapter 5 Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a Single Action (List Sweep)unit key ([G/n], [

Seite 37 - 2 Learning Operation Basics

Chapter 5 123Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a SingleAction (List Sweep)5. Setting Measureme

Seite 38 - Required Equipment

124 Chapter 5 Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a Single Action (List Sweep)previous segment a

Seite 39 - Preparing for a Measurement

Chapter 5 125Setting Measurement ConditionsSweeping Multiple Sweep Ranges with Different Conditions in a SingleAction (List Sweep)5. Setting Measureme

Seite 40 - Turn ON the Power

126 Chapter 5 Setting Measurement ConditionsSetting Measurement Accuracy, Stability, and TimeSetting Measurement Accuracy, Stability, and TimeSetting

Seite 41

Chapter 5 127Setting Measurement ConditionsSetting Measurement Accuracy, Stability, and Time5. Setting MeasurementConditionsAn = Sweep-to-sweep averag

Seite 42

128 Chapter 5 Setting Measurement ConditionsSetting Measurement Accuracy, Stability, and TimeEquation 5-2 Point Averaging Algorithmwhere:M = Point av

Seite 43

1296. Calibration6 CalibrationThis chapter describes calibration methods for the Agilent 4294A Precision Impedance Analyzer.

Seite 44

130 Chapter 6 CalibrationSelecting Appropriate Calibration MethodSelecting Appropriate Calibration MethodThe Agilent 4294A has three calibration types

Seite 45 - Connect the DUT

Chapter 6 131CalibrationSelecting Appropriate Calibration Method6. CalibrationRefer to the following sections for the calibration procedure of each de

Seite 46 - LIN key selected

6 Exclusive RemediesThe remedies provided herein are Buyer’s sole and exclusive remedies. Agilent Technologies shall not be liable for any direct, i

Seite 47 - SPLIT ON off)

132 Chapter 6 CalibrationSelecting Appropriate Calibration Method• “Selecting Calibration/Compensation Data Points” on page 155NOTE The user calibrat

Seite 48 - Auto-scale the q Trace

Chapter 6 133CalibrationA. Calibration When Using Direct Connection Type Test Fixture6. CalibrationA. Calibration When Using Direct Connection Type Te

Seite 49 - 2. Learning Operation Basics

134 Chapter 6 CalibrationA. Calibration When Using Direct Connection Type Test Fixture• 16089B Kelvin Clip Lead• 16089C Kelvin Clip Lead• 16089D Allig

Seite 50 - Results of Analysis

Chapter 6 135CalibrationB. Calibration for Four-Terminal Pair, 1-m Extension6. CalibrationB. Calibration for Four-Terminal Pair, 1-m ExtensionThis sec

Seite 51

136 Chapter 6 CalibrationB. Calibration for Four-Terminal Pair, 1-m Extension151.NOTE When the measurement port is extended by 1 meter with the four-t

Seite 52 - Front Panel

Chapter 6 137CalibrationC. Calibration for Four-Terminal Pair, 2-m Extension6. CalibrationC. Calibration for Four-Terminal Pair, 2-m ExtensionThis sec

Seite 53 - 2. MEASUREMENT Block

138 Chapter 6 CalibrationC. Calibration for Four-Terminal Pair, 2-m ExtensionStep 2. Perform the fixture compensation in accordance with “Fixture Comp

Seite 54 - 4. ENTRY Block

Chapter 6 139CalibrationD. Calibration When an Exclusive Fixture is Connected to the 42942A6. CalibrationD. Calibration When an Exclusive Fixture is C

Seite 55 - 6. INSTRUMENT STATE Block

140 Chapter 6 CalibrationD. Calibration When an Exclusive Fixture is Connected to the 42942ASee “Adapter Setting” on page 67 for adapter selection.St

Seite 56 - 9. Power Switch

Chapter 6 141CalibrationE. Calibration When the 7-mm Port of the 42942A is Extended6. CalibrationE. Calibration When the 7-mm Port of the 42942A is Ex

Seite 57 - 10. UNKNOWN Terminals

7• Programming Manual (Agilent P/N: 04294-900x1)The Programming Manual shows how to write and use BASIC program to control the Agilent 4294A and des

Seite 58 - Rear Panel

142 Chapter 6 CalibrationE. Calibration When the 7-mm Port of the 42942A is ExtendedNOTE In measurements using the 4294A, the electrical length (delay

Seite 59 - [Trigger]

Chapter 6 143CalibrationF. Calibration When a Probe Adapter is Connected to the 42941A6. CalibrationF. Calibration When a Probe Adapter is Connected t

Seite 60 - 14. Inlet (with a fuse box)

144 Chapter 6 CalibrationF. Calibration When a Probe Adapter is Connected to the 42941ASee “Adapter Setting” on page 67 for adapter selection.Step 2.

Seite 61 - Items Displayed on the LCD

Chapter 6 145CalibrationG. Calibration When the 3.5-mm Port of the 42941A is Extended6. CalibrationG. Calibration When the 3.5-mm Port of the 42941A i

Seite 62 - 5. Softkey Label Area

146 Chapter 6 CalibrationG. Calibration When the 3.5-mm Port of the 42941A is ExtendedStep 2. Perform the user calibration at the other end of the ext

Seite 63 - 7. Marker Status Fields

Chapter 6 147CalibrationUser Calibration6. CalibrationUser CalibrationUser calibration can be performed only when “42942A Terminal Adapter (7mm 42942A

Seite 64 - 9. Limit Line Test Fields

148 Chapter 6 CalibrationUser CalibrationWhen LOAD calibration data measurement is completed, the softkey label changes to LOAD [DONE].Step 12. Press

Seite 65

Chapter 6 149CalibrationUser Calibration6. CalibrationStep 2. Press the USER CAL key to display the User Calibration Menu.Step 3. Press the DEFINE VAL

Seite 66

150 Chapter 6 CalibrationPort Extension CompensationPort Extension CompensationPort extension compensation is used to compensate an error caused by th

Seite 67 - DATA MEM–

Chapter 6 151CalibrationFixture Compensation6. CalibrationFixture CompensationFixture compensation procedurePerform the fixture compensation as follow

Seite 69 - 21. Title Field

152 Chapter 6 CalibrationFixture CompensationStep 6. Press the OPEN key to start OPEN compensation data measurement.During the compensation data measu

Seite 70 - 62 Chapter 3

Chapter 6 153CalibrationFixture Compensation6. CalibrationTurning the fixture compensation on or offThe fixture compensation function is automatically

Seite 71

154 Chapter 6 CalibrationFixture CompensationStep 4. Select one of the compensation data definition keys, OPEN CONDUCT(G), OPEN CAP(C), SHORT RESIST(R

Seite 72

Chapter 6 155CalibrationSelecting Calibration/Compensation Data Points6. CalibrationSelecting Calibration/Compensation Data PointsYou can choose the t

Seite 73

156 Chapter 6 CalibrationSelecting Calibration/Compensation Data PointsList of fixed calibration/compensation frequency pointsWhen the fixed frequency

Seite 74 - Connecting the Accessories

1577. Setting Up the Display ofMeasurement Results7 Setting Up the Display of Measurement ResultsThis chapter describes how to configure the Agilent 4

Seite 75 - Adapter Setting

158 Chapter 7 Setting Up the Display of Measurement ResultsSelecting the Measurement ParametersSelecting the Measurement ParametersStep 1. Press the [

Seite 76 - Adapter Selection

Chapter 7 159Setting Up the Display of Measurement ResultsSelecting the Measurement Parameters7. Setting Up the Display ofMeasurement ResultsNOTE The

Seite 77

160 Chapter 7 Setting Up the Display of Measurement ResultsSelecting the Graph Axis FormatSelecting the Graph Axis FormatWhen Using Cartesian Coordina

Seite 78

Chapter 7 161Setting Up the Display of Measurement ResultsSelecting the Graph Axis Format7. Setting Up the Display ofMeasurement ResultsFigure 7-1 Ve

Seite 79 - PHASE COMP [DONE]

Contents 91. InstallationIncoming Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 80 - LOAD [DONE]

162 Chapter 7 Setting Up the Display of Measurement ResultsSelecting the Graph Axis FormatWhen Using Complex Parameters (COMPLEX Z-Y)When the Agilent

Seite 81

Chapter 7 163Setting Up the Display of Measurement ResultsSelecting the Graph Axis Format7. Setting Up the Display ofMeasurement ResultsFigure 7-4 Po

Seite 82 - PHASECOMP[DONE]

164 Chapter 7 Setting Up the Display of Measurement ResultsAuto-scaling the TraceAuto-scaling the TraceStep 1. Activate the trace you want auto-scaled

Seite 83

Chapter 7 165Setting Up the Display of Measurement ResultsAuto-scaling the Trace7. Setting Up the Display ofMeasurement ResultsFigure 7-6 After auto-

Seite 84 - OPEN [DONE]

166 Chapter 7 Setting Up the Display of Measurement ResultsManual Scale Setting (for measurements other than COMPLEX Z-Y)Manual Scale Setting (for mea

Seite 85 - SHORT [DONE]

Chapter 7 167Setting Up the Display of Measurement ResultsManual Scale Setting (for measurements other than COMPLEX Z-Y)7. Setting Up the Display ofMe

Seite 86

168 Chapter 7 Setting Up the Display of Measurement ResultsManual Scale Setting (for measurements other than COMPLEX Z-Y)Figure 7-8 Setting the refer

Seite 87

Chapter 7 169Setting Up the Display of Measurement ResultsManual Scale Setting (for measurements other than COMPLEX Z-Y)7. Setting Up the Display ofMe

Seite 88

170 Chapter 7 Setting Up the Display of Measurement ResultsManual Scale Setting (for measurements other than COMPLEX Z-Y)Figure 7-10 Setting the top

Seite 89

Chapter 7 171Setting Up the Display of Measurement ResultsManual Scale Setting (for measurements other than COMPLEX Z-Y)7. Setting Up the Display ofMe

Seite 90 - [Preset] key; once it is

10 Contents 2. MEASUREMENT Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 91 - Trace B [B]

172 Chapter 7 Setting Up the Display of Measurement ResultsManually Scaling the Active Trace for a COMPLEX Z-Y GraphManually Scaling the Active Trace

Seite 92 - Selecting Sweep Parameter

Chapter 7 173Setting Up the Display of Measurement ResultsManually Scaling the Active Trace for a COMPLEX Z-Y Graph7. Setting Up the Display ofMeasure

Seite 93

174 Chapter 7 Setting Up the Display of Measurement ResultsManually Scaling the Active Trace for a COMPLEX Z-Y Graphimpedance)Step 7. Press the SCALE/

Seite 94 - 86 Chapter 5

Chapter 7 175Setting Up the Display of Measurement ResultsManually Scaling the Active Trace for a COMPLEX Z-Y Graph7. Setting Up the Display ofMeasure

Seite 95

176 Chapter 7 Setting Up the Display of Measurement ResultsManually Scaling the Active Trace for a COMPLEX Z-Y GraphFigure 7-15 Setting the full scal

Seite 96 - Figure 5-4 Linear sweep

Chapter 7 177Setting Up the Display of Measurement ResultsSelecting the Target Trace Type (Data or Memory)7. Setting Up the Display ofMeasurement Resu

Seite 97

178 Chapter 7 Setting Up the Display of Measurement ResultsEnabling or Disabling Coupled Scaling ModeEnabling or Disabling Coupled Scaling ModeWhen bo

Seite 98 - MKR ® CENTER

Chapter 7 179Setting Up the Display of Measurement ResultsTrace-based Comparison and Calculation7. Setting Up the Display ofMeasurement ResultsTrace-b

Seite 99 - MKR ZOOM

180 Chapter 7 Setting Up the Display of Measurement ResultsTrace-based Comparison and CalculationNOTE At this time, you may want to hold (stop) the sw

Seite 100 - Figure 5-8

Chapter 7 181Setting Up the Display of Measurement ResultsTrace-based Comparison and Calculation7. Setting Up the Display ofMeasurement ResultsIn the

Seite 101

Contents 11Selecting Accessories for Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 102

182 Chapter 7 Setting Up the Display of Measurement ResultsTrace-based Comparison and CalculationFigure 7-17 Measuring reference data for comparison

Seite 103 - [Source] key

Chapter 7 183Setting Up the Display of Measurement ResultsTrace-based Comparison and Calculation7. Setting Up the Display ofMeasurement ResultsFigure

Seite 104 - 96 Chapter 5

184 Chapter 7 Setting Up the Display of Measurement ResultsTrace-based Comparison and Calculationon the measurement screen indicates a simplified expr

Seite 105

Chapter 7 185Setting Up the Display of Measurement ResultsSuperimposing Multiple Traces7. Setting Up the Display ofMeasurement ResultsSuperimposing Mu

Seite 106 - 98 Chapter 5

186 Chapter 7 Setting Up the Display of Measurement ResultsSuperimposing Multiple Tracespositions on the screen.Once you have turned on or off the tra

Seite 107 - Selecting Sweep Direction

Chapter 7 187Setting Up the Display of Measurement ResultsSuperimposing Multiple Traces7. Setting Up the Display ofMeasurement ResultsFigure 7-23 Com

Seite 108

188 Chapter 7 Setting Up the Display of Measurement ResultsSuperimposing Multiple Tracessearch within the segment (trace) only. For how to specify a p

Seite 109

Chapter 7 189Setting Up the Display of Measurement ResultsMonitoring the Test Signal Level (AC)7. Setting Up the Display ofMeasurement ResultsMonitori

Seite 110 - Setting with sweep time

190 Chapter 7 Setting Up the Display of Measurement ResultsMonitoring the Test Signal Level (AC)Figure 7-25 Monitoring signal source level (voltage/c

Seite 111 - Setting with sweep time delay

Chapter 7 191Setting Up the Display of Measurement ResultsMonitoring the Test Signal Level (AC)7. Setting Up the Display ofMeasurement Results(Trigger

Seite 113 - Setting Oscillator Level

12 ContentsSetting the Horizontal Axis of the Graph for the List Sweep. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Setting Me

Seite 114 - OSC UNIT [CURR] Current

192 Chapter 7 Setting Up the Display of Measurement ResultsMonitoring the Test Signal Level (AC)Figure 7-26 Using the marker-based monitoring feature

Seite 115 - Setting and Applying dc Bias

Chapter 7 193Setting Up the Display of Measurement ResultsMonitoring the dc Bias Level7. Setting Up the Display ofMeasurement ResultsMonitoring the dc

Seite 116

194 Chapter 7 Setting Up the Display of Measurement ResultsMonitoring the dc Bias LevelTraces A and B. Figure 7-27 Monitoring dc bias level with manu

Seite 117 - 6. Optimizing dc bias range

Chapter 7 195Setting Up the Display of Measurement ResultsMonitoring the dc Bias Level7. Setting Up the Display ofMeasurement ResultsStep 5. If the sw

Seite 118 - [] of the MEAS RANGE [ ] key

196 Chapter 7 Setting Up the Display of Measurement ResultsMonitoring the dc Bias Leveltrace is currently active. Traces A and B are each associated w

Seite 119

Chapter 7 197Setting Up the Display of Measurement ResultsSelecting the Phase Unit7. Setting Up the Display ofMeasurement ResultsSelecting the Phase U

Seite 120

198 Chapter 7 Setting Up the Display of Measurement ResultsDisplaying Phase Values without Wrapping at ±180°Displaying Phase Values without Wrapping a

Seite 121

Chapter 7 199Setting Up the Display of Measurement ResultsHiding the Non-active Trace7. Setting Up the Display ofMeasurement ResultsHiding the Non-act

Seite 122 - Sweep by specified times

200 Chapter 7 Setting Up the Display of Measurement ResultsSplitting the GraphSplitting the GraphYou can split the display into upper and lower halves

Seite 123 - Stopping sweep

Chapter 7 201Setting Up the Display of Measurement ResultsSplitting the Graph7. Setting Up the Display ofMeasurement ResultsFigure 7-30 Traces A and

Seite 124

Contents 13Monitoring the Test Signal Level on a Real-time Basis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189Using t

Seite 125

202 Chapter 7 Setting Up the Display of Measurement ResultsConfiguring the Screen Assignments for HP Instrument BASICConfiguring the Screen Assignment

Seite 126 - Preparing list sweep table

Chapter 7 203Setting Up the Display of Measurement ResultsConfiguring the Screen Assignments for HP Instrument BASIC7. Setting Up the Display ofMeasur

Seite 127

204 Chapter 7 Setting Up the Display of Measurement ResultsConfiguring the Screen Assignments for HP Instrument BASICFigure 7-33 Entire screen assign

Seite 128

Chapter 7 205Setting Up the Display of Measurement ResultsAdding a Title to the Measurement Screen7. Setting Up the Display ofMeasurement ResultsAddin

Seite 129

206 Chapter 7 Setting Up the Display of Measurement ResultsAdding a Title to the Measurement ScreenFigure 7-35 Adding a title to measurement screenNO

Seite 130 - 5 PRECISE

Chapter 7 207Setting Up the Display of Measurement ResultsCustomizing Intensity and Color Settings for Screen Display7. Setting Up the Display ofMeasu

Seite 131

208 Chapter 7 Setting Up the Display of Measurement ResultsCustomizing Intensity and Color Settings for Screen DisplayStep 5. Use the keys or rotary k

Seite 132

Chapter 7 209Setting Up the Display of Measurement ResultsCustomizing Intensity and Color Settings for Screen Display7. Setting Up the Display ofMeasu

Seite 133

210 Chapter 7 Setting Up the Display of Measurement ResultsCustomizing Intensity and Color Settings for Screen Displaythe saturation factor (%) relati

Seite 134

2118. Analysis and Processingof Result8 Analysis and Processing of ResultThis chapter describes how to analyze the result of measurements by the Agile

Seite 135 - AVERAGING ON off On

14 ContentsSimulate the frequency characteristics based on the equivalent circuit parameter. . . . . . . . . . . . . . . . . 252Calculating the mean

Seite 136 - POINT AVG ON off On

212 Chapter 8 Analysis and Processing of ResultSpecify the sweep parameter value and read the value on the traceSpecify the sweep parameter value and

Seite 137 - 6 Calibration

Chapter 8 213Analysis and Processing of ResultSpecify the sweep parameter value and read the value on the trace8. Analysis and Processingof ResultFigu

Seite 138

214 Chapter 8 Analysis and Processing of ResultListing data at several points on the traceListing data at several points on the traceWhen the main mar

Seite 139

Chapter 8 215Analysis and Processing of ResultListing data at several points on the trace8. Analysis and Processingof ResultFigure 8-2 Displaying the

Seite 140

216 Chapter 8 Analysis and Processing of ResultListing data at several points on the traceFigure 8-3 Listing marker positions with the marker list fu

Seite 141

Chapter 8 217Analysis and Processing of ResultReading the difference from the reference point on the screen (delta marker)8. Analysis and Processingof

Seite 142

218 Chapter 8 Analysis and Processing of ResultReading the difference from the reference point on the screen (delta marker)When you select the delta m

Seite 143 - 4TP 1M).”

Chapter 8 219Analysis and Processing of ResultReading the difference from the reference point on the screen (delta marker)8. Analysis and Processingof

Seite 144 - 4294A is

220 Chapter 8 Analysis and Processing of ResultReading the difference from the reference point on the screen (delta marker)• “Specify the sweep parame

Seite 145 - 4TP 2M).”

Chapter 8 221Analysis and Processing of ResultReading the difference from the reference point on the screen (delta marker)8. Analysis and Processingof

Seite 146

Contents 15Performing Self-Diagnosis of the Agilent 4294A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320P

Seite 147 - 7mm 42942A).”

222 Chapter 8 Analysis and Processing of ResultReading actual measurement points only/reading interpolated values between measurement pointsReading ac

Seite 148

Chapter 8 223Analysis and Processing of ResultSearch the maximum/minimum measurements8. Analysis and Processingof ResultSearch the maximum/minimum mea

Seite 149 - Extended

224 Chapter 8 Analysis and Processing of ResultSearch the maximum/minimum measurementsFigure 8-7 Minimum search value by traceNOTE When the MAX, MIN,

Seite 150

Chapter 8 225Analysis and Processing of ResultSearch the point of target measurement8. Analysis and Processingof ResultSearch the point of target meas

Seite 151 - PROBE 42941A).”

226 Chapter 8 Analysis and Processing of ResultSearch the point of target measurementFigure 8-8 Result of target value search (Trace B)NOTE If multip

Seite 152

Chapter 8 227Analysis and Processing of ResultSearch the point of target measurement8. Analysis and Processingof ResultFigure 8-9 Right search after

Seite 153

228 Chapter 8 Analysis and Processing of ResultSearch the maximum/minimum peakSearch the maximum/minimum peakThe peak search function enables the main

Seite 154

Chapter 8 229Analysis and Processing of ResultSearch the maximum/minimum peak8. Analysis and Processingof ResultPeak menu to also place the sub-marker

Seite 155 - User Calibration

230 Chapter 8 Analysis and Processing of ResultSearch the maximum/minimum peakFigure 8-11 Search the next peak after Figure 8-10 using the NEXT PEAK

Seite 156 - CORRECTION ON off On

Chapter 8 231Analysis and Processing of ResultSearch the maximum/minimum peak8. Analysis and Processingof ResultFigure 8-13 Search the left-hand peak

Seite 157

16 ContentsSoftkeys displayed by pressing the [Format] key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Seite 158 - Port Extension Compensation

232 Chapter 8 Analysis and Processing of ResultDefine the PeakDefine the PeakWhen peaks are defined, unwanted peaks can be excluded so that only the p

Seite 159 - Fixture Compensation

Chapter 8 233Analysis and Processing of ResultDefine the Peak8. Analysis and Processingof ResultDefine peak sharpnessThe following steps are used to d

Seite 160

234 Chapter 8 Analysis and Processing of ResultDefine the Peak“Search the maximum/minimum peak” on page 228. It should be noted, however, that a defi

Seite 161

Chapter 8 235Analysis and Processing of ResultAutomatically performing search for each sweep (search tracking)8. Analysis and Processingof ResultAutom

Seite 162

236 Chapter 8 Analysis and Processing of ResultAnalyze trace bandwidthAnalyze trace bandwidthThe Agilent 4294A can automatically derive the parameters

Seite 163 - COMP POINT [USER]

Chapter 8 237Analysis and Processing of ResultAnalyze trace bandwidth8. Analysis and Processingof ResultBandwidth: Indicates the interval of sweep par

Seite 164

238 Chapter 8 Analysis and Processing of ResultAnalyze trace bandwidthFigure 8-15 Trace bandwidth analysis function (different definition for each D

Seite 165 - Measurement Results

Chapter 8 239Analysis and Processing of ResultAnalyze trace bandwidth8. Analysis and Processingof ResultStep 4. Select the definition of the cutoff po

Seite 166 - 1. Quality factor

240 Chapter 8 Analysis and Processing of ResultAnalyze trace bandwidthbandwidth analysis.When you have selected the delta marker mode, the delta marke

Seite 167

Chapter 8 241Analysis and Processing of ResultAnalyze trace bandwidth8. Analysis and Processingof ResultBandwidth Analysis Result area on the right of

Seite 168

171. Installation1 InstallationThis chapter contains installation and setup instructions for the Agilent 4294A Precision Impedance Analyzer. For infor

Seite 169

242 Chapter 8 Analysis and Processing of ResultAnalyze trace bandwidthpeak value.If the two cutoff points cannot be found by trace bandwidth analysis,

Seite 170

Chapter 8 243Analysis and Processing of ResultSet the marker separately for either trace A or B8. Analysis and Processingof ResultSet the marker separ

Seite 171

244 Chapter 8 Analysis and Processing of ResultSelecting target trace (data or memory) for marker analysisSelecting target trace (data or memory) for

Seite 172 - Auto-scaling the Trace

Chapter 8 245Analysis and Processing of ResultSelecting the sweep parameter value of the marker display as time from startor relaxation time8. Analysi

Seite 173

246 Chapter 8 Analysis and Processing of ResultSelecting the sweep parameter value of the marker display as time from start or relaxation timeFigure 8

Seite 174 - COMPLEX Z-Y)

Chapter 8 247Analysis and Processing of ResultClearing (turning off) the marker from the screen8. Analysis and Processingof ResultClearing (turning of

Seite 175

248 Chapter 8 Analysis and Processing of ResultClearing (turning off) the marker from the screenStep 2. Press the [Marker] key to display the Marker m

Seite 176

Chapter 8 249Analysis and Processing of ResultCalculate the equivalent circuit parameter and simulate the frequencycharacteristics8. Analysis and Proc

Seite 177

250 Chapter 8 Analysis and Processing of ResultCalculate the equivalent circuit parameter and simulate the frequency characteristicsFigure 8-19 Equiv

Seite 178

Chapter 8 251Analysis and Processing of ResultCalculate the equivalent circuit parameter and simulate the frequencycharacteristics8. Analysis and Proc

Seite 179

18 Chapter 1 InstallationIncoming InspectionIncoming InspectionWARNING To avoid hazardous electrical shock, do not turn on the Agilent 4294A if there

Seite 180

252 Chapter 8 Analysis and Processing of ResultCalculate the equivalent circuit parameter and simulate the frequency characteristicsWhen the equivalen

Seite 181

Chapter 8 253Analysis and Processing of ResultCalculate the equivalent circuit parameter and simulate the frequencycharacteristics8. Analysis and Proc

Seite 182

254 Chapter 8 Analysis and Processing of ResultCalculating the mean value, standard deviation, and peak-to-peak of the traceCalculating the mean value

Seite 183

Chapter 8 255Analysis and Processing of ResultCalculating the mean value, standard deviation, and peak-to-peak of thetrace8. Analysis and Processingof

Seite 184

256 Chapter 8 Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluationSet a limit to the trace and make pass/fail evalu

Seite 185 - SCALE FOR [MEMO] Memory trace

Chapter 8 257Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation8. Analysis and Processingof ResultStep 2. Activat

Seite 186

258 Chapter 8 Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation• Press the step keys ([][¯]) to set the desired

Seite 187 - Comparison or Calculation

Chapter 8 259Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation8. Analysis and Processingof Result• Enter the val

Seite 188

260 Chapter 8 Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation(2) Move the main marker to the position of the s

Seite 189 - DATA/MEM

Chapter 8 261Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation8. Analysis and Processingof ResultFigure 8-25 Co

Seite 190 - DATA and MEMORY key)

Chapter 1 19InstallationIncoming Inspection1. Installation1. The number of “x” in the part number of each manual or sample program disk, 0 for the fir

Seite 191 - DELTA % key)

262 Chapter 8 Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluationConduct the limit line testAfter completing the l

Seite 192 - Subtracting an Offset Value

Chapter 8 263Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation8. Analysis and Processingof ResultFigure 8-27 Li

Seite 193 - Superimposing Multiple Traces

264 Chapter 8 Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation• In the even of a failure, the limit line test f

Seite 194

Chapter 8 265Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluation8. Analysis and Processingof ResultFigure 8-29 Li

Seite 195

266 Chapter 8 Analysis and Processing of ResultSet a limit to the trace and make pass/fail evaluationFigure 8-30 Limit line movement by offset (- 10

Seite 196 - 188 Chapter 7

Chapter 8 267Analysis and Processing of ResultSpecify partial search range8. Analysis and Processingof ResultSpecify partial search rangeUnder the pre

Seite 197

268 Chapter 8 Analysis and Processing of ResultSpecify partial search rangeFigure 8-31 Minimum value search by turning on partial search rangeNOTE T

Seite 198

Chapter 8 269Analysis and Processing of ResultSpecify partial search range8. Analysis and Processingof ResultWhen the sweep type is list sweep:Step 1.

Seite 199

270 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataSave and Recall the Agilent 4294A Internal DataThe Agile

Seite 200 - 192 Chapter 7

Chapter 8 271Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultNOTE Before saving the

Seite 201 - Monitoring the dc Bias Level

20 Chapter 1 InstallationPrecautions to Take Before Setting Up the Power Supply Precautions to Take Before Setting Up the Power SupplyBefore supplying

Seite 202 - To: Pres s:

272 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataNOTE When using the floppy disk drive, make sure a disk

Seite 203

Chapter 8 273Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultNOTE There is no need

Seite 204

274 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataStep 7. Select the save on/off for the following data (t

Seite 205 - Selecting the Phase Unit

Chapter 8 275Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultNOTE There is no need

Seite 206

276 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataTable 8-5 Example of data saved in the text (ASCII) for

Seite 207 - Hiding the Non-active Trace

Chapter 8 277Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultStructure of data save

Seite 208 - Splitting the Graph

278 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Dataexpressed as an underscore (_). Strings including instru

Seite 209 - ALL INSTRUMENT or

Chapter 8 279Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof Resultcalibration data and t

Seite 210 - BASIC STATUS

280 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataContents of the data part when saving the data array Ta

Seite 211

Chapter 8 281Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultTable 8-12 shows the c

Seite 212 - 204 Chapter 7

Chapter 1 21InstallationPower Cable1. InstallationPower CableIn accordance with international safety standards, the Agilent 4294A uses a three-wire po

Seite 213

282 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataTable 8-15 is an example of the data part when specifyin

Seite 214

Chapter 8 283Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultData contents saved in

Seite 215

284 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataTable 8-18 Specified measurement parameter and saved da

Seite 216

Chapter 8 285Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultSaving a data array in

Seite 217

286 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataNOTE You do not need to add any extension to the file na

Seite 218

Chapter 8 287Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultNow look at the struct

Seite 219 - 8. Analysis and Processing

288 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataThe second and later lines are data lines. The contents

Seite 220

Chapter 8 289Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultThe setting of the sto

Seite 221

290 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal DataThe extension ".TIF" is automatically added to

Seite 222

Chapter 8 291Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultFile Select menu serve

Seite 223

Safety SummaryWhen you notice any of the unusual conditions listed below, immediatelyterminate operation and disconnect the power cable.Contact your l

Seite 224

22 Chapter 1 InstallationPower CableFigure 1-2 Alternative Power Cable Options

Seite 225 - (delta marker)

292 Chapter 8 Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Datadevice by the STORE DEV [ ] key.To store the power as

Seite 226

Chapter 8 293Analysis and Processing of ResultSave and Recall the Agilent 4294A Internal Data8. Analysis and Processingof ResultStep 5. When the file

Seite 227

294 Chapter 8 Analysis and Processing of ResultPrint the measurement results and internal data with a printerPrint the measurement results and interna

Seite 228

Chapter 8 295Analysis and Processing of ResultPrint the measurement results and internal data with a printer8. Analysis and Processingof ResultNOTE Th

Seite 229

296 Chapter 8 Analysis and Processing of ResultPrint the measurement results and internal data with a printerStep 10. Press the more 1/2 key to displa

Seite 230

Chapter 8 297Analysis and Processing of ResultPrint the measurement results and internal data with a printer8. Analysis and Processingof Resultthe Cop

Seite 231

298 Chapter 8 Analysis and Processing of ResultPrint the measurement results and internal data with a printerFigure 8-34 List of measurement conditio

Seite 232

2999. Setting/Using Control andManagement Functions9 Setting/Using Control and Management FunctionsThis section describes how to set/use the control a

Seite 233

300 Chapter 9 Setting/Using Control and Management FunctionsRe-displaying an Instrument MessageRe-displaying an Instrument MessageA message displayed

Seite 234 - SEARCH RIGHT

Chapter 9 301Setting/Using Control and Management FunctionsSetting/Checking the Internal Clock9. Setting/Using Control andManagement FunctionsSetting/

Seite 235 - SUB MKR key located on the

Chapter 1 23InstallationConnecting the BNC Adapter (for Option 1D5 Only)1. Installation Connecting the BNC Adapter (for Option 1D5 Only)When Option 1D

Seite 236

302 Chapter 9 Setting/Using Control and Management FunctionsSetting/Checking the Internal ClockStep 7. Press the DAY key. In the set parameter value f

Seite 237 - PEAK key

Chapter 9 303Setting/Using Control and Management FunctionsSetting/Checking the Internal Clock9. Setting/Using Control andManagement FunctionsSteps 6

Seite 238 - 230 Chapter 8

304 Chapter 9 Setting/Using Control and Management FunctionsSetting the Built-in Speaker (Beep Sound)Setting the Built-in Speaker (Beep Sound)The Agil

Seite 239 - NEXT PEAK LEFT key

Chapter 9 305Setting/Using Control and Management FunctionsManaging Files9. Setting/Using Control andManagement FunctionsManaging FilesThe Agilent 429

Seite 240 - Define the Peak

306 Chapter 9 Setting/Using Control and Management FunctionsManaging FilesTo create a new directory in a location other than the current directory, pr

Seite 241 - Define peak sharpness

Chapter 9 307Setting/Using Control and Management FunctionsManaging Files9. Setting/Using Control andManagement FunctionsNOTE You can perform Steps 10

Seite 242

308 Chapter 9 Setting/Using Control and Management FunctionsManaging Filestarget file as a softkey label.• You can scroll the softkey label file/direc

Seite 243

Chapter 9 309Setting/Using Control and Management FunctionsManaging Files9. Setting/Using Control andManagement FunctionsNOTE Each of the following me

Seite 244 - Analyze trace bandwidth

310 Chapter 9 Setting/Using Control and Management FunctionsManaging FilesNOTE You can perform Steps 11 and 12 with the external keyboard connected to

Seite 245

Chapter 9 311Setting/Using Control and Management FunctionsManaging Files9. Setting/Using Control andManagement FunctionsStep 8. Press the softkey cor

Seite 246

24 Chapter 1 InstallationUsing the LAN PortUsing the LAN PortYou can connect the Agilent 4294A to a local area network by using the RJ-45J UTP (Unshie

Seite 247

312 Chapter 9 Setting/Using Control and Management FunctionsManaging FilesIn [] of the STORE DEV [ ] key's key label, the selected storage device

Seite 248

Chapter 9 313Setting/Using Control and Management FunctionsSetting/Checking the GPIB9. Setting/Using Control andManagement FunctionsSetting/Checking t

Seite 249 - SEARCH OUT

314 Chapter 9 Setting/Using Control and Management FunctionsSetting/Checking the LANSetting/Checking the LANThis section describes how to set or check

Seite 250

Chapter 9 315Setting/Using Control and Management FunctionsSetting/Checking the LAN9. Setting/Using Control andManagement Functions• Turn the rotary k

Seite 251

316 Chapter 9 Setting/Using Control and Management FunctionsSetting/Checking the LANStep 5. Press the 2nd key. In the set parameter value field in the

Seite 252 - MKR ON [MEMORY] Memory trace

Chapter 9 317Setting/Using Control and Management FunctionsSetting/Checking the LAN9. Setting/Using Control andManagement FunctionsSetting/Checking th

Seite 253

318 Chapter 9 Setting/Using Control and Management FunctionsSetting/Checking the LANStep 10. Use the keys or rotary knob of the ENTRY block in one of

Seite 254 - 246 Chapter 8

Chapter 9 319Setting/Using Control and Management FunctionsChecking the Firmware Version9. Setting/Using Control andManagement FunctionsChecking the F

Seite 255 - Turning off the delta marker

320 Chapter 9 Setting/Using Control and Management FunctionsPerforming Self-Diagnosis of the Agilent 4294APerforming Self-Diagnosis of the Agilent 429

Seite 256 - MKR ON off ON (displayed)

Chapter 9 321Setting/Using Control and Management FunctionsPerforming Self-Diagnosis of the Agilent 4294A9. Setting/Using Control andManagement Functi

Seite 257

Chapter 1 25InstallationConnecting the Keyboard1. Installation Connecting the Keyboard1Step 1. Insert the cable of the Mini-DIN keyboard into the keyb

Seite 258 - A, B, C, D or E

322 Chapter 9 Setting/Using Control and Management FunctionsPerforming Self-Diagnosis of the Agilent 4294A

Seite 259

32310. Specifications and Supplemental PerformanceCharacteristics10 Specifications and Supplemental Performance Characteristics

Seite 260

324 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsSpecifications describe the instrument's warranted

Seite 261

Chapter 10 325Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 262 - STATISTICS on OFF Off

326 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsSignal Level MonitorNOTE f: frequency [MHz], Zx: impeda

Seite 263

Chapter 10 327Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 264 - Set the limit line

328 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsFigure 10-1 dc Bias Range (SPC)Sweep CharacteristicsAv

Seite 265

Chapter 10 329Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 266

330 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsAdapter SetupCalibrationMeasurement AccuracyAccuracy Sp

Seite 267

Chapter 10 331Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 268

26 Chapter 1 InstallationUsing a Rackmount KitUsing a Rackmount KitIf you want to combine the Agilent 4294A with other instruments and a controller to

Seite 269 - CLEAR LIST - yes (cancel)

332 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsNOTE Dx: measurement value of D.Qx: measurement value o

Seite 270 - Conduct the limit line test

Chapter 10 333Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 271 - BEEP FAIL ON off ON (beeps)

334 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsNOTE SPC at frequency > 10 MHz.KBW =at measurement B

Seite 272 - Step 4. Press the

Chapter 10 335Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 273 - + 1 kHz)

336 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsNOTE f: frequency in MHz.VmV: oscillator level in mV.Im

Seite 274 - - 10 degrees)

Chapter 10 337Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 275 - Specify partial search range

338 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsNOTE f: frequency in MHz.VmV: oscillator level in mV.Te

Seite 276 - MKRD ® SEARCH RNG

Chapter 10 339Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 277

340 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsParameters Yo , Ep , and ZsFigure 10-3 Parameters Yo ,

Seite 278

Chapter 10 341Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 279 - [Preset] key

Chapter 1 27InstallationUsing a Rackmount Kit1. InstallationStep 3. Attach the trim strips (4) to the handles.Option 1CM Rackmount KitOption 1CM incl

Seite 280 - 4294A through the HP

342 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsFigure 10-5 Impedance Measurement Accuracy at 7-mm Por

Seite 281

Chapter 10 343Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 282

344 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsDisplay FunctionsMarker FunctionsDisplay Size/Type 8.4

Seite 283

Chapter 10 345Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 284

346 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsGPIBHP Instrument BASIC8-Bit I/O PortFigure 10-7 8 Bit

Seite 285 - Table 8-6 Data structure

Chapter 10 347Specifications and Supplemental Performance CharacteristicsBasic Characteristics10. Specifications and Supplemental PerformanceCharacter

Seite 286

348 Chapter 10 Specifications and Supplemental Performance CharacteristicsBasic CharacteristicsLAN Interface21 Input/Output port C0 TTL level, latch o

Seite 287

Chapter 10 349Specifications and Supplemental Performance CharacteristicsGeneral Characteristics10. Specifications and Supplemental PerformanceCharact

Seite 288 - (part of trace A)

350 Chapter 10 Specifications and Supplemental Performance CharacteristicsGeneral CharacteristicsFigure 10-9 Required Pulse Width (Tp) for External T

Seite 289

Chapter 10 351Specifications and Supplemental Performance CharacteristicsGeneral Characteristics10. Specifications and Supplemental PerformanceCharact

Seite 290

28 Chapter 1 InstallationEnvironmental RequirementsEnvironmental RequirementsThe Agilent 4294A is designed to operate under the following environmenta

Seite 291

352 Chapter 10 Specifications and Supplemental Performance CharacteristicsGeneral CharacteristicsFigure 10-10 Dimensions (front view, with Option 1CN

Seite 292

Chapter 10 353Specifications and Supplemental Performance CharacteristicsGeneral Characteristics10. Specifications and Supplemental PerformanceCharact

Seite 293

354 Chapter 10 Specifications and Supplemental Performance CharacteristicsFurnished AccessoriesFurnished AccessoriesAgilent Part Number11. The number

Seite 294

355A. Manual ChangesA Manual ChangesThis appendix contains the information required to adapt this manual to versions or configurations of the Agilent

Seite 295

356 A Manual ChangesManual ChangesTo adapt this manual to your 4294A, refer to Table A-1 and Table A-2.Agilent Technologies uses a two-part, ten-chara

Seite 296

A 357Manual ChangesChange to the revision 1.0xA. Manual ChangesChange 1The firmware before the revision 1.0x does not support the following function.•

Seite 297 - Table 8-22

358 A Manual ChangesChange to the revision 1.0xMiscellaneous ChangesThe option system of the 4294A has changed since February 2003. Apply the followin

Seite 298

359B. Key DefinitionsB Key DefinitionsThis chapter describes the functions of the front keys (both hardkeys and softkeys) of the Agilent 4294A.

Seite 299 - Directory name\

360 Appendix B Key DefinitionsFunctions of hardkeysFunctions of hardkeysThis section describes the function and corresponding GPIB command for each ha

Seite 300 - Recall the saved file

Appendix B 361Key DefinitionsFunctions of hardkeysB. Key DefinitionsTable B-4 MARKER blockHardkey Function GPIB command[Marker] Displays the marker a

Seite 301

292. Learning Operation Basics2 Learning Operation BasicsThis chapter guides you through a tour of the basic measurement functions of the Agilent 4294

Seite 302 - IMAGE COLOR

362 Appendix B Key DefinitionsFunctions of hardkeys[Back Space] Moves the cursor one space back and deletes the character to the left of the cursor. I

Seite 303

Appendix B 363Key DefinitionsSoftkeys displayed by pressing the [Meas] keyB. Key DefinitionsSoftkeys displayed by pressing the [Meas] keyTable B-7 Me

Seite 304

364 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Meas] keyTable B-9 Measurement parameter (Measurement) menu (3/3)Key operation: [Me

Seite 305

Appendix B 365Key DefinitionsSoftkeys displayed by pressing the [Format] keyB. Key DefinitionsSoftkeys displayed by pressing the [Format] keyTable B-1

Seite 306

366 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Display] keySoftkeys displayed by pressing the [Display] keyTable B-13 Display (Dis

Seite 307 - Functions

Appendix B 367Key DefinitionsSoftkeys displayed by pressing the [Display] keyB. Key DefinitionsTable B-15 Trace definition (Define Trace) menuKey ope

Seite 308

368 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Display] keyTable B-17 Title menuKey operation: [Display] - more 1/2 - TITLESoftkey

Seite 309 - Setting/Checking the Date

Appendix B 369Key DefinitionsSoftkeys displayed by pressing the [Display] keyB. Key DefinitionsTable B-19 Equivalent circuit selection (Select Circ)

Seite 310 - Setting/Checking the Time

370 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Display] keyHALF INSTR HALF BASIC |Uses the upper half of the screen as the instrume

Seite 311

Appendix B 371Key DefinitionsSoftkeys displayed by pressing the [Display] keyB. Key DefinitionsTRC B MEM LIMIT LINE |Selects the trace B memory trace,

Seite 312 - BEEP WARN on OFF Off

30 Chapter 2 Learning Operation BasicsRequired EquipmentRequired EquipmentTo perform all of the steps in this tour, you must have the following equipm

Seite 313 - Managing Files

372 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Display] keyPEN 4 |Selects PEN 41 as the display item that can be changed with the M

Seite 314

Appendix B 373Key DefinitionsSoftkeys displayed by pressing the [Scale Ref] keyB. Key DefinitionsSoftkeys displayed by pressing the [Scale Ref] keyTab

Seite 315 - Copying a File

374 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Scale Ref] keymore 2/2 Displays Table B-27, “Scale reference (Scale Ref) menu (1-1/2

Seite 316

Appendix B 375Key DefinitionsSoftkeys displayed by pressing the [Scale Ref] keyB. Key DefinitionsD&M COUPLE ON OFF When both the data trace and th

Seite 317

376 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Bw/Avg] keySoftkeys displayed by pressing the [Bw/Avg] keyTable B-32 Measurement ba

Seite 318 - Deleting a File or Directory

Appendix B 377Key DefinitionsSoftkeys displayed by pressing the [Bw/Avg] keyB. Key Definitions 3 |Selects 3 as the measurement bandwidth (during list

Seite 319 - FLASH MEMORY

378 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Cal] keySoftkeys displayed by pressing the [Cal] keyTable B-34 Calibration (Calibra

Seite 320

Appendix B 379Key DefinitionsSoftkeys displayed by pressing the [Cal] keyB. Key DefinitionsSETUP ä Displays Table B-36, “Adapter setup (Adapter Setup)

Seite 321 - Setting/Checking the GPIB

380 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Cal] keyTable B-37 Fixture compensation (Fixture Comp) menuKey operation: [Cal] - F

Seite 322 - Setting/Checking the LAN

Appendix B 381Key DefinitionsSoftkeys displayed by pressing the [Cal] keyB. Key DefinitionsTable B-39 User calibration (User Cal) menuKey operation:

Seite 323

Chapter 2 31Learning Operation BasicsPreparing for a Measurement2. Learning Operation BasicsPreparing for a MeasurementPrepare the Agilent 4294A for m

Seite 324

382 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Cal] key1. Though the softkey labels are the same as those in Table B-38, “Calibrati

Seite 325

Appendix B 383Key DefinitionsSoftkeys displayed by pressing the [Sweep] keyB. Key DefinitionsSoftkeys displayed by pressing the [Sweep] keyTable B-43

Seite 326 - Checking the MAC Address

384 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Sweep] keyreturn Returns to Table B-43, “Sweep (Sweep) menu,” on page 383. (N/A)Tab

Seite 327 - Checking the Firmware Version

Appendix B 385Key DefinitionsSoftkeys displayed by pressing the [Sweep] keyB. Key DefinitionsPEN Sets the pen number for the trace of the list sweep s

Seite 328

386 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Sweep] keyBIAS MODE [ ] ä Displays Table B-51, “DC bias mode (DC Bias Mode) menu,” o

Seite 329

Appendix B 387Key DefinitionsSoftkeys displayed by pressing the [Sweep] keyB. Key DefinitionsTable B-51 DC bias mode (DC Bias Mode) menuKey operation

Seite 330 - 322 Chapter 9

388 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Source] keySoftkeys displayed by pressing the [Source] keyTable B-53 Source oscilla

Seite 331 - Performance Characteristics

Appendix B 389Key DefinitionsSoftkeys displayed by pressing the [Source] keyB. Key Definitions10mA |Selects < 10 mA (less than 10 mA) as the dc bia

Seite 332 - Basic Characteristics

390 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Trigger] keySoftkeys displayed by pressing the [Trigger] keyTable B-56 Trigger (Tri

Seite 333

Appendix B 391Key DefinitionsSoftkeys displayed by pressing the [Trigger] keyB. Key Definitionsreturn Returns to Table B-56, “Trigger (Trigger) menu,”

Seite 335

32 Chapter 2 Learning Operation BasicsPreparing for a MeasurementTurn ON the PowerPress the power switch to turn on the power to the Agilent 4294A.The

Seite 336 - Sweep Characteristics

392 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Marker] keySoftkeys displayed by pressing the [Marker] keyTable B-58 Marker (Marker

Seite 337 - Trigger Function

Appendix B 393Key DefinitionsSoftkeys displayed by pressing the [Marker] keyB. Key Definitions6: OFF For sub marker 6, executes the same operation as

Seite 338 - Measurement Accuracy

394 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Marker] keyDMKR STIMULUS For the selected D marker (D marker, fixed D marker, or tra

Seite 339

Appendix B 395Key DefinitionsSoftkeys displayed by pressing the [Marker®] keyB. Key DefinitionsSoftkeys displayed by pressing the [Marker®] keyTable B

Seite 340

396 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Marker®] keyMKR ZOOM Substitutes the sweep parameter value at the main marker on the

Seite 341

Appendix B 397Key DefinitionsSoftkeys displayed by pressing the [Search] keyB. Key DefinitionsSoftkeys displayed by pressing the [Search] keyTable B-6

Seite 342

398 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Search] keyTable B-65 Target (Ta rget) menuKey operation: [Search] - TARGETSoftkey

Seite 343

Appendix B 399Key DefinitionsSoftkeys displayed by pressing the [Search] keyB. Key DefinitionsSUB MKR ä Displays Table B-59, “Sub marker configuration

Seite 344 -

400 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Search] keyTable B-68 Trace bandwidth analysis definition (Widths Def) menuKey oper

Seite 345

Appendix B 401Key DefinitionsSoftkeys displayed by pressing the [Search] keyB. Key DefinitionsMKR ® MAXIMUM Substitutes the sweep parameter value at t

Seite 346

Chapter 2 33Learning Operation BasicsSpecifying Measurement Conditions2. Learning Operation BasicsSpecifying Measurement ConditionsNext, you need to s

Seite 347

402 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Utility] keySoftkeys displayed by pressing the [Utility] keyTable B-71 Utility (Uti

Seite 348 - Parameters Yo , Ep , and Zs

Appendix B 403Key DefinitionsSoftkeys displayed by pressing the [Utility] keyB. Key DefinitionsTable B-73 Level monitor (Level Mon) menuKey operation

Seite 349

404 Appendix B Key DefinitionsSoftkeys displayed by pressing the [System] keySoftkeys displayed by pressing the [System] keyTable B-74 System (System

Seite 350 - 342 Chapter 10

Appendix B 405Key DefinitionsSoftkeys displayed by pressing the [System] keyB. Key Definitionsmore 1/3 Displays Table B-76, “HP Instrument BASIC (IBAS

Seite 351

406 Appendix B Key DefinitionsSoftkeys displayed by pressing the [System] keymore 2/3 Displays Table B-77, “HP Instrument BASIC (IBASIC) menu (3/3),”

Seite 352 - Marker Functions

Appendix B 407Key DefinitionsSoftkeys displayed by pressing the [System] keyB. Key DefinitionsOUTPUT @Hp4294 Inserts OUTPUT @Hp4294 TO 800 at the curr

Seite 353 - Parallel Printer Port

408 Appendix B Key DefinitionsSoftkeys displayed by pressing the [System] keyCLEAR NAME Deletes all entered characters. (N/A)done Finishes the entry o

Seite 354 - 8-Bit I/O Port

Appendix B 409Key DefinitionsSoftkeys displayed by pressing the [System] keyB. Key DefinitionsTable B-83 Limit line edit (Edit Limit) menuKey operati

Seite 355

410 Appendix B Key DefinitionsSoftkeys displayed by pressing the [System] keyMIDDLE VALUE Sets the limit center value of the measured value at the swe

Seite 356 - LAN Interface

Appendix B 411Key DefinitionsSoftkeys displayed by pressing the [System] keyB. Key DefinitionsDELTA LIMIT Sets the limit center value of the measured

Seite 357 - General Characteristics

34 Chapter 2 Learning Operation BasicsSpecifying Measurement ConditionsStep 2. Press the LOG key to select Log (logarithmic) sweep. Set the Sweep Star

Seite 358 - Operating Conditions

412 Appendix B Key DefinitionsSoftkeys displayed by pressing the [System] keyTable B-87 List deletion (Clear List?) menuKey operation: [System] - LIM

Seite 359 - Other Specifications

Appendix B 413Key DefinitionsSoftkeys displayed by pressing the [System] keyB. Key DefinitionsTable B-90 Time configuration (Set Time) menuKey operat

Seite 360 - 352 Chapter 10

414 Appendix B Key DefinitionsSoftkeys displayed by pressing the [System] keyEXTERNAL TEST|Refer to “Service Manual.” (N/A)DISPLAY TEST Refer to “Serv

Seite 361

Appendix B 415Key DefinitionsSoftkeys displayed by pressing the [Local] keyB. Key DefinitionsSoftkeys displayed by pressing the [Local] keyTable B-94

Seite 362 - Furnished Accessories

416 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Local] keycancel Cancels setting the IP address, gateway address, or subnet address

Seite 363 - A Manual Changes

Appendix B 417Key DefinitionsSoftkeys displayed by pressing the [Copy] keyB. Key DefinitionsSoftkeys displayed by pressing the [Copy] keyTable B-98 C

Seite 364 - Manual Changes

418 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Copy] keyTable B-100 Copy configuration (Copy Setup) menu (2/2)Key operation: [Copy

Seite 365 - Change 1

Appendix B 419Key DefinitionsSoftkeys displayed by pressing the [Copy] keyB. Key DefinitionsTable B-102 Copy data (Copy Contents) menuKey operation:

Seite 366 - Miscellaneous Changes

420 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Copy] keyTable B-104 Limit test segment copy start (Copy Contents) menuKey operatio

Seite 367 - B Key Definitions

Appendix B 421Key DefinitionsSoftkeys displayed by pressing the [Save] keyB. Key DefinitionsSoftkeys displayed by pressing the [Save] keyTable B-105

Seite 368 - Functions of hardkeys

Chapter 2 35Learning Operation BasicsFixture Compensation2. Learning Operation BasicsFixture CompensationNext, you need to eliminate errors produced b

Seite 369 - Table B-6 ENTRY block

422 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Save] keydone Using the entered string as the filename, executes storing states, dat

Seite 370

Appendix B 423Key DefinitionsSoftkeys displayed by pressing the [Save] keyB. Key DefinitionsTable B-109 Power-on configuration save (Save config?) me

Seite 371 - [Meas] key

424 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Save] keyTable B-111 File selection (Select File) menuKey operation: [System] - PRO

Seite 372 - Key Definitions

Appendix B 425Key DefinitionsSoftkeys displayed by pressing the [Save] keyB. Key DefinitionsTable B-113 Format confirmation (Format Media?) menuKey o

Seite 373 - [Format] key

426 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Save] keyreturn Returns to Table B-114, “Copy destination filename (Dest File) menu,

Seite 374 - [Display] key

Appendix B 427Key DefinitionsSoftkeys displayed by pressing the [Recall] keyB. Key DefinitionsSoftkeys displayed by pressing the [Recall] keyTable B-1

Seite 375 - B. Key Definitions

428 Appendix B Key DefinitionsSoftkeys displayed by pressing the [Recall] key

Seite 376 - Table B-17 Title menu

429C. Error messagesC Error messagesThe Agilent 4294A provides error messages to indicate its operating status. This appendix describes the error mess

Seite 377 - Appendix B 369

430 Appendix C Error messagesADC OVERLOADNOTE If an error with a positive error number occurs, only its error message is displayed on the LCD followin

Seite 378 - 370 Appendix B

Appendix C 431Error messagesBlock data errorC. Error messagesmemory (SRAM), which stores user calibration data, fixture compensation data, GP-IB addre

Seite 379 - Appendix B 371

36 Chapter 2 Learning Operation BasicsFixture CompensationFigure 2-3 Setting Up the Test Circuit for SHORT CompensationStep 2. Press the SHORT key to

Seite 380 - 372 Appendix B

432 Appendix C Error messagesCALIBRATION NOT USABLEfour-terminal pair extension.12 CALIBRATION NOT USABLEA command to execute data measurement for unn

Seite 381 - [Scale Ref] key

Appendix C 433Error messagesCAN'T SAVE GRAPHICS WHEN COPY IN PROGRESSC. Error messagesthe minimum frequency and the maximum frequency, respective

Seite 382 - 374 Appendix B

434 Appendix C Error messagesData out of memoryThe data may be invalid. Otherwise, a newly initiated read operation may not have been completed since

Seite 383 - Appendix B 375

Appendix C 435Error messagesEEPROM WRITE FAILC. Error messagesE194 EEPROM WRITE FAILA write error is detected in the memory (EEPROM) to store the OPEN

Seite 384 - [Bw/Avg] key

436 Appendix C Error messagesFREQUENCY SWEEP ONLYWhen a measurement parameter other than COMPLEX Z-Y (i.e., scalar parameter measurement) is selected,

Seite 385 - Appendix B 377

Appendix C 437Error messagesInit ignoredC. Error messagesThe variable name is illegal. This message is displayed when you attempt to refer to a variab

Seite 386 - [Cal] key

438 Appendix C Error messagesInvalid string dataThe parser (syntax analysis program) expects a separator, but a character other than a separator is se

Seite 387 - Appendix B 379

Appendix C 439Error messagesMemory errorC. Error messagesand a floppy disk is write-protected. If necessary, disable the write-protection of the flopp

Seite 388 - 380 Appendix B

440 Appendix C Error messagesNO STATE/DATA FILES ON MEMORYsoftkey labels with the recall ([Recall]) key, file re-save (RE-SAVE FILE) key, file deletio

Seite 389 - Appendix B 381

Appendix C 441Error messagesOSC LEVEL MONITOR NOT VALIDC. Error messagesO140 OSC LEVEL MONITOR NOT VALIDWhen the oscillator level monitor is not on, y

Seite 390 - 382 Appendix B

Chapter 2 37Learning Operation BasicsCarrying Out Measurement and Viewing Results2. Learning Operation BasicsCarrying Out Measurement and Viewing Resu

Seite 391 - [Sweep] key

442 Appendix C Error messagesProgram mnemonic too longAn error occurred in a downloaded program. A program error other than -281 to -289 occurred.-112

Seite 392 - 384 Appendix B

Appendix C 443Error messagesREDUCE OSC LEVELC. Error messageserror occurs, for example, when data in a file to be read out is destroyed or when an ext

Seite 393 - Appendix B 385

444 Appendix C Error messagesSuffix not allowedA suffix error. An error other than -131 to -139 occurs in the notation of a suffix.-138 Suffix not all

Seite 394 - 386 Appendix B

Appendix C 445Error messagesTrigger errorC. Error messagesThe received block, equation, or string type program data comply with the standard, but the

Seite 395 - Appendix B 387

446 Appendix C Error messagesWRONG I/O PORT DIRECTION

Seite 396

447D. Initial SettingsD Initial SettingsThis appendix provides initial settings, settings that can be saved/recalled, and settings that can be backed

Seite 397 - Appendix B 389

448 Appendix D Initial SettingsInitial Settings, Settings that can be Saved/Recalled, Settings that can be Backed UpInitial Settings, Settings that ca

Seite 398 - [Trigger] key

Appendix D 449Initial SettingsInitial Settings, Settings that can be Saved/Recalled, Settings that can beBacked UpD. Initial SettingsTable D-1 Initia

Seite 399 - Appendix B 391

450 Appendix D Initial SettingsInitial Settings, Settings that can be Saved/Recalled, Settings that can be Backed UpDisplay On/Off (GPIB Command only)

Seite 400 - [Marker] key

Appendix D 451Initial SettingsInitial Settings, Settings that can be Saved/Recalled, Settings that can beBacked UpD. Initial SettingsFixture compensat

Seite 401 - Appendix B 393

38 Chapter 2 Learning Operation BasicsCarrying Out Measurement and Viewing ResultsFigure 2-5 Measurement results displayed just after connecting the

Seite 402 - 394 Appendix B

452 Appendix D Initial SettingsInitial Settings, Settings that can be Saved/Recalled, Settings that can be Backed UpAnalysis Equivalent circuit analys

Seite 403 - [Marker®] key

Appendix D 453Initial SettingsInitial Settings, Settings that can be Saved/Recalled, Settings that can beBacked UpD. Initial SettingsPrinter Color Bla

Seite 404 - 396 Appendix B

454 Appendix D Initial SettingsInitial Settings, Settings that can be Saved/Recalled, Settings that can be Backed Up

Seite 405 - [Search] key

IndexIndex 455IndexSymbols-, 56*, 56, 57?, 56Numerics[0]-[9][.][-] keys, 4616034E, 6416034G, 6416034H, 6416044A, 6416047A, 6416047C, 6416047D, 641604

Seite 406 - Table B-66 Peak (Peak) menu

456 Index IndexCW frequency, 104DD marker mode, 56data arraydata contents saved with the data save function, 280data block, 277data part, 277data cont

Seite 407

IndexIndex 457Indexrecording medium, 311inlet with a fuse box, 52installation, 17keyboard, 25rackmount kit, 26instrument messagedisplaying again, 300

Seite 408 - 400 Appendix B

458 Index IndexPPeak, 55peakdefinition, 232phase unit, 197point averaging, 127algorithm, 128POR, 58Por, 58port extension compensation, 150powercable,

Seite 409 - Appendix B 401

IndexIndex 459Indextrace bandwidth, 236trace datadata contents saved with the data save function, 279trace math, 179triggerevent, 112function, 329sou

Seite 411 - Appendix B 403

REGIONAL SALES AND SUPPORT OFFICESFor more information about Agilent Technologies test and measurement products, applications, services, andfor a curr

Seite 412 - [System] key

Chapter 2 39Learning Operation BasicsCarrying Out Measurement and Viewing Results2. Learning Operation BasicsFigure 2-6 Result of Applying the Logari

Seite 413 - Appendix B 405

40 Chapter 2 Learning Operation BasicsCarrying Out Measurement and Viewing ResultsFigure 2-7 Displaying Traces A and B in ParallelNOTE You do not nee

Seite 414 - 406 Appendix B

Chapter 2 41Learning Operation BasicsCarrying Out Measurement and Viewing Results2. Learning Operation BasicsFigure 2-8 Results of Auto-scaling

Seite 416 - 408 Appendix B

42 Chapter 2 Learning Operation BasicsResults of Analysis Results of Analysis Determine the Self-resonance Frequency and Resonant ImpedanceStep 1. Pr

Seite 417 - Appendix B 409

433. Front/Rear Panel andLCD Display3 Front/Rear Panel and LCD DisplayThis chapter covers the features of the front and rear panels of the Agilent 429

Seite 418 - 410 Appendix B

44 Chapter 3 Front/Rear Panel and LCD DisplayFront PanelFront PanelThe front panel of the Agilent 4294A provides several blocks of hardkeys and an LCD

Seite 419 - Appendix B 411

Chapter 3 45Front/Rear Panel and LCD DisplayFront Panel3. Front/Rear Panel andLCD DisplayNOTE As a typographic convention to distinguish between hardk

Seite 420 - 412 Appendix B

46 Chapter 3 Front/Rear Panel and LCD DisplayFront Panel 3. STIMULUS BlockThis block provides keys for configuring the test signal parameters. 4. ENT

Seite 421 - Appendix B 413

Chapter 3 47Front/Rear Panel and LCD DisplayFront Panel3. Front/Rear Panel andLCD Display5. MARKER BlockThe MARKER block provides keys for configuring

Seite 422 - 414 Appendix B

48 Chapter 3 Front/Rear Panel and LCD DisplayFront Panelmeasurement or analysis. 7. SoftkeysThe softkeys are eight keys located along the right-hand e

Seite 423 - [Local] key

Chapter 3 49Front/Rear Panel and LCD DisplayFront Panel3. Front/Rear Panel andLCD Display10. UNKNOWN TerminalsThese connectors let you connect the ins

Seite 424 - 416 Appendix B

50 Chapter 3 Front/Rear Panel and LCD DisplayRear PanelRear PanelFigure 3-2 Rear Panel1. External Reference Input ConnectorAllows you to connect an e

Seite 425 - [Copy] key

Chapter 3 51Front/Rear Panel and LCD DisplayRear Panel3. Front/Rear Panel andLCD Display3. External Trigger InputAllows you to input a TTL-compatible

Seite 427 - Appendix B 419

52 Chapter 3 Front/Rear Panel and LCD DisplayRear Panelto use an unsupported keyboard.10. 24-bit I/O PortProvides a data communications interface with

Seite 428 - 420 Appendix B

Chapter 3 53Front/Rear Panel and LCD DisplayItems Displayed on the LCD3. Front/Rear Panel andLCD DisplayItems Displayed on the LCDFigure 3-3 Items di

Seite 429 - [Save] key

54 Chapter 3 Front/Rear Panel and LCD DisplayItems Displayed on the LCD5. Softkey Label AreaShows the labels that are, in the current context, associa

Seite 430 - 422 Appendix B

Chapter 3 55Front/Rear Panel and LCD DisplayItems Displayed on the LCD3. Front/Rear Panel andLCD DisplayNOTE Some softkey labels combine two or more o

Seite 431 - Appendix B 423

56 Chapter 3 Front/Rear Panel and LCD DisplayItems Displayed on the LCDcompleted. Peak Indicates that the marker facility is currently in search tra

Seite 432 - 424 Appendix B

Chapter 3 57Front/Rear Panel and LCD DisplayItems Displayed on the LCD3. Front/Rear Panel andLCD Displayon the dc bias monitor feature through the key

Seite 433 - Appendix B 425

58 Chapter 3 Front/Rear Panel and LCD DisplayItems Displayed on the LCDV ¯ Indicates that, because you specified dc voltage bias (in constant voltag

Seite 434 - 426 Appendix B

Chapter 3 59Front/Rear Panel and LCD DisplayItems Displayed on the LCD3. Front/Rear Panel andLCD Display Fixture compensation statusBlank cells in the

Seite 435 - [Recall] key

60 Chapter 3 Front/Rear Panel and LCD DisplayItems Displayed on the LCDService mode statusSvc Indicates that the instrument is in service mode, whic

Seite 436 - 428 Appendix B

Chapter 3 61Front/Rear Panel and LCD DisplayItems Displayed on the LCD3. Front/Rear Panel andLCD Displaymessages,” on page 429.21. Title FieldThis fi

Seite 437 - C Error messages

Caution Do not exceed the operating input power, voltage, and currentlevel and signal type appropriate for the instrument being used, refer toyour in

Seite 438

62 Chapter 3 Front/Rear Panel and LCD DisplayItems Displayed on the LCD

Seite 439

634. Preparation ofMeasurement Accessories4 Preparation of Measurement AccessoriesThis chapter describes the required preparation of accessories after

Seite 440

64 Chapter 4 Preparation of Measurement AccessoriesSelecting Accessories for MeasurementSelecting Accessories for MeasurementSelect the appropriate ac

Seite 441

Chapter 4 65Preparation of Measurement AccessoriesSelecting Accessories for Measurement4. Preparation ofMeasurement AccessoriesNOTE The 16085B Termina

Seite 442

66 Chapter 4 Preparation of Measurement AccessoriesConnecting the AccessoriesConnecting the AccessoriesStep 1. Connect the measurement accessories to

Seite 443

Chapter 4 67Preparation of Measurement AccessoriesAdapter Setting4. Preparation ofMeasurement AccessoriesAdapter SettingYou must ensure that the adapt

Seite 444

68 Chapter 4 Preparation of Measurement AccessoriesAdapter SettingAdapter SelectionThe adapter selection setting must be confirmed before measurement

Seite 445

Chapter 4 69Preparation of Measurement AccessoriesAdapter Setting4. Preparation ofMeasurement AccessoriesNOTE Adapter selection status can also be con

Seite 446

70 Chapter 4 Preparation of Measurement AccessoriesAdapter SettingNOTE When you select “No Adapter” (NONE key) in adapter selection, adapter setup can

Seite 447

Chapter 4 71Preparation of Measurement AccessoriesAdapter Setting4. Preparation ofMeasurement AccessoriesNOTE The 16048G or 16048H cable must be direc

Seite 449

72 Chapter 4 Preparation of Measurement AccessoriesAdapter SettingFigure 4-3 Connecting 100 W Resister (Load Data Measurement)Step 8. Press the LOAD

Seite 450

Chapter 4 73Preparation of Measurement AccessoriesAdapter Setting4. Preparation ofMeasurement AccessoriesAgilent 4294A.NOTE The 16334A must be directl

Seite 451

74 Chapter 4 Preparation of Measurement AccessoriesAdapter SettingDuring each data measurement, the message “WAIT--MEASURING ADJUSTMENT KIT” is displa

Seite 452

Chapter 4 75Preparation of Measurement AccessoriesAdapter Setting4. Preparation ofMeasurement AccessoriesKIT” is displayed in the instrument state are

Seite 453

76 Chapter 4 Preparation of Measurement AccessoriesAdapter SettingFigure 4-5 Connecting OPEN (0 S) to the 42942AStep 6. Press the PHASE COMP [-] key

Seite 454 - WRONG I/O PORT DIRECTION

Chapter 4 77Preparation of Measurement AccessoriesAdapter Setting4. Preparation ofMeasurement AccessoriesFigure 4-6 Connecting SHORT (0 W) to the 429

Seite 455 - D Initial Settings

78 Chapter 4 Preparation of Measurement AccessoriesAdapter SettingFigure 4-7 Connecting LOAD (50 W) to the 42942AStep 11. Press the LOAD [-] key to s

Seite 456

Chapter 4 79Preparation of Measurement AccessoriesAdapter Setting4. Preparation ofMeasurement AccessoriesStep 1. Make sure that the 42941A is correctl

Seite 457 - D. Initial Settings

80 Chapter 4 Preparation of Measurement AccessoriesAdapter SettingNOTE When the load data measurement is completed, the softkey label changes to OPEN

Seite 458 - 450 Appendix D

815. Setting MeasurementConditions5 Setting Measurement ConditionsThis chapter explains how to set up the measurement conditions for the Agilent 4294A

Seite 459 - Appendix D 451

Agilent 4294A Precision Impedance AnalyzerOperation ManualSeventh EditionFIRMWARE REVISIONSThis manual applies directly to instruments that have the f

Seite 460 - 452 Appendix D

82 Chapter 5 Setting Measurement ConditionsPutting the Agilent 4294A into the Preset State (Presetting)Putting the Agilent 4294A into the Preset State

Seite 461 - Appendix D 453

Chapter 5 83Setting Measurement ConditionsSelecting Trace (Active Trace)5. Setting MeasurementConditionsSelecting Trace (Active Trace) The Agilent 429

Seite 462 - 454 Appendix D

84 Chapter 5 Setting Measurement ConditionsSelecting Sweep ParameterSelecting Sweep ParameterStep 1. Press the [Sweep] key.Step 2. Press the PARAMETER

Seite 463 - Index 455

Chapter 5 85Setting Measurement ConditionsSelecting Sweep Parameter5. Setting MeasurementConditionsFigure 5-1 Sweep by FrequencyFigure 5-2 Sweep by

Seite 464 - 456 Index

86 Chapter 5 Setting Measurement ConditionsSelecting Sweep ParameterFigure 5-3 Sweep by dc current bias (Constant dc bias current mode)

Seite 465 - Index 457

Chapter 5 87Setting Measurement ConditionsSelecting Linear, Log, or List Sweep5. Setting MeasurementConditionsSelecting Linear, Log, or List SweepStep

Seite 466 - 458 Index

88 Chapter 5 Setting Measurement ConditionsSelecting Linear, Log, or List SweepFigure 5-4 Linear sweepFigure 5-5 Log (logarithm) sweep

Seite 467 - Index 459

Chapter 5 89Setting Measurement ConditionsSetting Sweep Range5. Setting MeasurementConditionsSetting Sweep RangeSweep range can be set by specifying e

Seite 468

90 Chapter 5 Setting Measurement ConditionsSetting Sweep Range• Press the step keys ([][¯]) to set the desired value.Step 3. Press the [Stop] key. Th

Seite 469

Chapter 5 91Setting Measurement ConditionsSetting Sweep Range5. Setting MeasurementConditionsNOTE After you change the sweep range, the trace for the