Agilent Technologies 6612B Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Multimeter Agilent Technologies 6612B herunter. Agilent Technologies 6612B Technical data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Instrument Controller

Agilent OL Instrument Controller Installation and Configuration Guide

Seite 2 - Notices

this button. A dialog box appears asking you if you want to close the window. Click Yes. 9. Immediately disconnect the crossover cable from the Agile

Seite 3 - Contents

Figure 2. AIC 5000 Instrument and SS420x Connections Plug the SS420x power supply into an appropriate electrical outlet. Connect the power cord from

Seite 4

If you are using an instrument with an analog signal, you need to connect it to an SS420x attached to the Agilent Instrument Controller using the conn

Seite 5 - 2 Before You Start

1. From OL, select the Administration tab and then click Global Administration, followed by Agilent Instrument Controller. 2. Double-click the name

Seite 6 - 2 Using This Guide

Baud Rate The communication baud rate is displayed. To change the baud rate, click Set Baud Rate. Base Frequency Select the base frequency. The defau

Seite 7

Configure Instruments Before you can use the Agilent Instrument Controller to acquire data, each instrument must be configured using the Agilent OL s

Seite 8 - 4 Installing the AIC 5000

Important notes for the Reset to Factory Adapter • The Reset to Factory Adapter will cause a reset to factory defaults on any AIC, not just the one i

Seite 9 - Installing the AIC 5000 5

6 AIC 5000 Specifications Dimensions Height 3.95 inches 10.3 cm Width 13.3 inches 33.78 cm Depth 15.1 inches 38.35 cm Approximate Weight

Seite 10 - Install the SS420x

Note This system utilizes a passive power factor corrected power supply when used in the 230V mode. This allows the system to pass the CE mark requi

Seite 11 - Connect the Instruments

7 Installing AIC Revision B for Agilent OL Use this procedure for the Agilent Instrument Controller Revision B. Revision B of the AIC is silver in

Seite 12 - Select Components

Notices Copyright © Scientific Software, Inc 1997-2005 © Agilent Technologies, Inc. 2005-2007. No part of this manual may be reproduced in any form or

Seite 13 - Configure the SS420x

Figure 1. AIC Connectors for Revision B 7. Power on the Agilent Instrument Controller and wait 5 minutes for initialization. The AIC will “beep” wh

Seite 14 - 10 Installing the AIC 5000

2. Log in as Admin with no password. (Admin is case-sensitive.) 3. On the General tab, enter the following information: Name: for addressing the A

Seite 15 - Configure Instruments

several possibilities, given below. Once you have resolved the problem, go back to the beginning of this section and repeat the steps to set up the A

Seite 16 - 12 Installing the AIC 5000

Note If you are using a SCSI instrument, it must be powered ON prior to connecting it to the Agilent Instrument Controller. If you are using an instr

Seite 17 - 6 AIC 5000 Specifications

3. Select each hardware component for this Agilent Instrument Controller by clicking the box adjacent to the component name. You may select as many

Seite 18 - 14 Installing the AIC 5000

Base Frequency Select the base frequency. The default setting for the SS420x is 10 Hz, which gives optimal signal to noise, and can be used in count

Seite 19 - Appliance

Configure Instruments Before you can use the Agilent Instrument Controller to acquire data, each instrument must be configured using the OL software.

Seite 20 - 16 Installing AIC Rev. B

8 Installing AIC Revision A for Agilent OL Use this procedure to install Revision A of the Agilent Instrument Controller. Revision A is black in co

Seite 21 - Installing AIC Rev. B 17

Figure 1. 1a Not used 1b USB connection 2a Not used 2b USB connection 3,4a Monitor connection 4b Serial port connection 5 Not used 6 Not used 9 N

Seite 22

Comment: any additional comment you want to make OL server URL: for example http://aspen. 4. On the Hardware tab, click the Configure link and make

Seite 23

Contents 1 Using This Guide... 1 Introduction ...

Seite 24

• The laboratory network cable was not connected soon enough after clicking Initialize (see steps 5-6, above). Install the SS420x If your instrument

Seite 25 - Installing AIC Rev. B 21

details on how to connect an instrument to the SS420x, see the documentation provided with the SS420x. Finish Configuring the Instrument Controller 1

Seite 26

to confirm the installation. If this is not the first installation, go to the Advanced tab and click Restart. The system will display the “Installin

Seite 27

countries). If selected incorrectly, you may see line frequency noise on your chromatogram. For best performance, select a base frequency close to

Seite 28

30 Installing AIC Revision A

Seite 29

9 Using the Reset to Factory Adapter for AIC Rev A/B The Agilent Instrument Controller (AIC) (Rev A and B only) is shipped with a USB flash drive th

Seite 30

• If you remove the special file on the Reset to Factory Adapter or rename it, then the device will no longer cause a reset to factory. Don’t use th

Seite 31

10 Updating an AIC This section applies only to the Revision A and Revision B versions of the Agilent Instrument Controller. For support purposes, i

Seite 32

34 Updating an AIC

Seite 33

12 Specifications for AIC Rev A and B Agilent Instrument Controller Revisions A and B Environment Operating temperature: 0oC to 40oC (32oF to 10

Seite 34

Install the SS420x...18 Connect the Instruments ...

Seite 35

Printed in the U.S.A. February, 2007 *G4650-90017* G4650-90017

Seite 36

1 Using This Guide Introduction This guide describes how to install the Agilent Instrument Controller (AIC) for use with Agilent OL. The Agilent In

Seite 37 - 11 Notes

Note Place the AIC 5000 on a flat, stable surface. You can position the unit in the upright position using the included stand, or in the horizontal p

Seite 38 - 34 Updating an AIC

3 Installing AIC 5000 for Agilent OL Use this procedure for installing and configuring the Agilent Instrument Controller AIC 5000. The AIC 5000 is b

Seite 39

5. Disconnect the computer from the network and change the TCP/IP settings to use the static IP address 192.168.1.2. Contact a network administrator

Seite 40 - *G4650-90017*

Configure the Agilent Instrument Controller Device 1. From the configuration computer (see “Before You Start” section), open Internet Explorer and g

Kommentare zu diesen Handbüchern

Keine Kommentare