86100 family plug-in module matrix
The 86100 has a family of plug-in modules designed for a broad range of precision optical, electrical, and TDR/TDT measurements. The 86100 can ac-
commodate up to 4 modules for a total of 16 measurement channels.
www.agilent.com/find/dcax
Agilent 86100D Wide-Bandwidth Oscilloscope Selection Table
Filtered data rates
86105C
6
100
2
1 1 750-1650 8.5 20 62.5 -20 ● ● ● ● ● ● ● ● ● ● ●
200 1 1 750-1650 8.5 20 62.5 -16 ● ● ● ● ● ● ●
●
300
2
1 1 750-1650 8.5 20 62.5 -16 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
●
86105D
3,6
1 1 750-1650 20 35 62.5 -12 ● ● ● ● ● ● ● ●
●
100 1 1 750-1650 20 35 62.5 -12 ● ● ● ● ● ● ● ●
200 1 1 750-1650 20 35 62.5 -12 ●
281 1 1 750-1650 34 50 62.5 -8 ● ● ●
86115D
3,6
002 2 0 750-1650 20 62.5 -12 ● ● ● ● ● ● ● ●
●
102 2 0 750-1650 20 62.5 -12 ● ● ● ● ● ● ● ●
142 2 0 750-1650 20 62.5 -12 ●
004
5
4 0 750-1650 20 62.5 -11 ● ● ● ● ● ● ● ●
●
104 4 0 750-1650 20 62.5 -11 ● ● ● ● ● ● ● ●
144 4 0 750-1650 20 62.5 -11 ●
282 2 0 750-1650 34 62.5 -8 ● ● ●
86116C
3,6
025 1 1 1300-
1620
45 80 9 -10
● ●
86116C
3,6
041 1 1 1300-
1620
65 80 9 -5
● ● ●
54754A 0 2 ● ● N/A 18
86108A
3,4
0 2 ● N/A 32
86108B
3,4
LBW 0 2 ● N/A 35
HBW 0 2 ● N/A 50
86112A 0
2 N/A 20
HBW 0 2 ● N/A 30
86117A 0 2 N/A 50
86118A 0 2 N/A 70
N1045A 0 2-4 N/A 60
N1055A 0 2-4 ● N/A 50
Module
Option
No. of optical channels
No. of electrical channels
TDR/TDT/S-parameters
Probe power
1
Wavelength range (nm)
Unfiltered optical bandwidth (GHz)
Electrical bandwidth (GHz)
Fiber input (µm)
Mask test sensitivity (dBm)
155 Mb/s
622 Mb/s
1063 Mb/s
1244/1250 Mb/s
2125 Mb/s
2488/2500 Mb/s
2.666 Gb/s
3.125 Gb/s
4.25 Gb/s
5.00 Gb/s
6.25 Gb/s
8.50 Gb/s
9.953 Gb/s
10.3125 Gb/s
10.51875 Gb/s
10.664 Gb/s
10.709 Gb/s
11.096 Gb/s
11.317 Gb/s
14.025 Gb/s
25.80 Gb/s
27.70 Gb/s
28.025 Gb/s
39.813 Gb/s
41.250 Gb/s
43.018 Gb/s
1. Module has receptacle to supply power for external probe.
2. Pick any 4 rates (155 Mb/s to 6.25 Gb/s).
3. This module is not compatible with the 86100A and 86100B Digital Communication Analyzer (DCA) mainframes. If you would like to upgrade older DCA’s contact
Agilent Technologies and ask for current trade-in deals.
4. The 86108A/B uses all module slots.
5. 4 optical input ports are switched internally to 2 optical-to-electrical (O/E) converter
6. All modules with optical channels can use option -IRC to enhance the effective operating range. Reference receivers can be created at any rate within +/-50% of the
hardware capability. IRC also corrects hardware imperfections to yield ideal reference receiver responses.