116 Agilent E6474A User’s Guide
4 Use Your System
Table 6 on page 116 in step 6. Average noise level = (Marker 1
level + Marker 2 level) / 2
Tabl e 5 Noise Floor Frequency Settings for Step 6
Tabl e 6 Noise Floor Frequency Settings for Step 11
The measurement is making 100 averages, which requires
approximately three minutes to stabilize the noise level. After
completion, stop the measurement and note the levels.
Passing the Test
You have passed the test if the average noise level is below –122
dBm. If your system is equipped with a navigator, perform the
tests in Table 5 on page 116. If you experience problems in
setting up the test, refer to “Solving Problems with Your
System" on page 130.
Model Marker 1 Frequency (step 6)
PCS CDMA and TDMA band systems 1959 MHz
GSM DCS1800 band systems 1843 MHz
GSM900 band systems 943 MHz
Cellular CDMA and TDMA band systems 882 MHz
Model Marker 1 Frequency (step 6)
PCS CDMA and TDMA band systems 1879 MHz
GSM DCS1800 band systems 1745 MHz
GSM900 band systems 898 MHz
Cellular CDMA and TDMA band systems 837 MHz