Two-tone
Frequency spacing 100 Hz to 80 MHz (symmetrical about carrier)
IM distortion
250 kHz to 3.2 GHz < –45 dBc for RF levels < 0 dBm (typical)
>3.2 GHz to 20 GHz < –55 dBc for RF levels < 0 dBm (typical)
Measured two-tone
Basic modulation types (custom format)
PSK BPSK, QPSK, OQPSK, π/4DQPSK, 8PSK, 16PSK, D8PSK
MSK User-defined phase offset from 0 to 100°
QAM 4, 16, 32, 64, 256
FSK Selectable: 2, 4, 8, 16 level symmetric
User defined Custom map of up to 16 deviation levels
Symbol rate Maximum deviation
< 5 MHz 4 times symbol rate
5 MHz to 50 MHz 20 MHz
Resolution: 0.1 Hz
I/Q Custom map of 256 unique values
Vector accuracy
1
Formats: BPSK, QPSK, 16-256QAM
(α= 0.3, Root Nyquist filter, symbol rate 4 Msym/s)
EVM < 1.2% RMS, < 0.8% RMS (typical)
Origin offset
250 kHz to 3.2 GHz –45 dBc (typical)
3.2 to 20 GHz –50 dBc (typical)
FIR filter
Selectable Nyquist, root Nyquist, Gaussian, rectangular
α: 0 to 1, B
b
T: 0.1 to 1
Custom FIR 16-bit resolution, up to 64 symbols long, automatically
resampled to 1024 coefficients (max)
> 32 to 64 symbol filter: symbol rate 12.5 MHz
> 16 to 32 symbol filter: symbol rate 25 MHz
Internal filters switch to 16 tap when symbol rate is
between 25 and 50 MHz
Symbol rate
For external serial data: Adjustable from 1000 symbols/sec to a maximum symbol
rate of 50 Mbits/sec ÷ #bits/symbol
For internally generated data: Adjustable from 1000 symbols/sec to 50 Msymbols/sec.
and a maximum of 8 bits per symbol. Modulation quality
may be degraded at high symbol rates.
Baseband reference frequency Data clock can be phase locked to an external reference.
Input ECL, CMOS, TTL compatible, 50 AC coupled
Internal baseband generator:
real-time mode
(Option 602)
Ref-4 dBm
Samp
Log
10
dB/
LgAv
10
W1 S2
S3 FC
(f):
#f>50K
#Swp
#Atten 6 dB
Mkr1 -20.00 MHz
-62.275 dB
Center 20.000 00 GHz
Res BW 470 kHz
VBW 470 kHz
Span 50 MHz
Sweep 1 ms
Marker
-20.000000 MHz
-62.275 dB
1. Measured with Agilent 89441A Vector Signal Analyzer. Valid after executing I/Q calibration, and instrument is
maintained within ± 5 °C of calibration temperature. RF power < 0 dBm. When external inputs are used, vector
accuracy can approach internal performance after system optinization. Recommended external I/Q input level
(I
2
+ Q
2
) = 0.3 V
rms
, I/Q modulator attenuator = 10 dB.