Seite 1 - Self Guided Demo

Agilent E8247C/E8257CPSG CW and Analog Signal GeneratorsSelf Guided DemoProduct Note

Seite 2

10Instruction Note7. Highlight the frequency item for point 8, then press {Insert Item}.NOTE During this process, several error messages are generat

Seite 3 - Table of Contents

11The 8257C can modulate the RF car-rier with four types of analog modu-lation: amplitude, frequency, phase,and pulse.AM, FM, and ΦΦM Sources•AM, FM,

Seite 4 - Configuring the RF Output

12Instruction Note1. Press [Frequency] > [4] > {GHz}. The FREQUENCY area of the display now reads 4.000 000 000 00 GHz.Instruction Note1. Pres

Seite 5

13Creating a multipath AM configurationUse these steps to configure a multi-path AM configuration. AM Path 1and AM Path 2 are summed inter-nally for c

Seite 6

14Instruction Note1. Press [Preset].2. Press [Frequency] > [4] > {GHz}. The Center FREQUENCY area of the display now reads 4.000 000 00 GHz.3.

Seite 7 - List Sweep

15Activating FMThe signal generator is now config-ured to output a 0 dBm, frequency-modulated carrier at 4 GHz with theFM deviation set to 75 kHz and

Seite 8

16Configuring ΦΦMUsing this procedure, you will learnhow to create a phase-modulated RFcarrier with the following character-istics:•RF output frequenc

Seite 9 - Editing list sweep points

17Configuring pulse modulationUsing the following procedure youwill learn how to create a pulse-modulated RF carrier with the fol-lowing characteristi

Seite 10 - Activating List Sweep for

18The E8257C has a low frequency(LF) output. The LF output’s sourcecan be switched between an internalmodulation source (internal monitor1 or 2) or an

Seite 11 - (E8257C Only)

19Instruction Note1. Press [Preset].2. Press the [FM/ΦM] hardkey.3. Press {FM Dev} > [75] > {kHz}. This sets the FM deviation to 75 kHz.4. Press

Seite 12 - Configuring AM

2Agilent E8247C 250 kHz - 40 GHz PSG CW signal generatorAgilent E8257C 250 kHz - 40 GHz PSG analog signal generator

Seite 13 - Activating a multipath

20This section explains how to usethe two forms of signal generatordata storage, the memory cata-log, and the instrument stateregister.Using the memor

Seite 14 - E4440A PSA spectrum analyzer

21Instruction Note1. Press [Utility] > {Memory Catalog} The default catalog type is All (all files in the > {Catalog Type}. memory catalog are

Seite 15

22Using the instrument state registerThe instrument state register is asection of memory divided into 10 sequences (numbered 0 through9), each contain

Seite 16

23Instruction Note1. Press [Preset].2. Configure the signal generator with the following settings:a. Press [Frequency] > [800] > {MHz}.b. Pres

Seite 17 - Configuring pulse modulation

24Instruction Note1. Press [Preset].2. Press the [Recall] or [Save] hardkey. Notice that the {Select Seq} softkey shows the lastsequence that you used

Seite 18

25The PSG signal generator uses tableeditors to simplify configurationtasks such as creating a list sweep.Using the List Mode Values table edi-tor, th

Seite 19

26This section will show you how toconfigure the signal generator tointerface with a remote controller.Follow the instructions in the appro-priate sec

Seite 20 - Storage Functions

27Instruction Note1. Press [Utility] > {GPIB/RS-232 LAN} > {RS-232 Setup}.2. Press {RS-232 Baud Rate}. Press the desired baud rate softkey to

Seite 21 - Storing files

Product specifications and descriptions in this document subject to change without notice.© Agilent Technologies, Inc. 2001, 2002Printed in USA Octobe

Seite 22

3Part 1: Configuring the RF Output 2Part 2: Configuring Analog Modulation (E8257C Only) 20Part 3: Configuring the LF Output (E8257C Only) 22Part 4:

Seite 23

4This section explains how to create continuous wave and swept RF outputs.Instruction Note1. Press [Preset]. This returns the signal generator to the

Seite 24

5Setting the frequency reference and frequency offsetThe following procedure sets the RF output frequency as a referencefrequency to which all other f

Seite 25 - Part 5: Using Table Editors

6Setting the amplitude reference andamplitude offsetThe following procedure sets the RF output power as an amplitudereference to which all other ampli

Seite 26 - Remote Control

7Step sweep allows you to enter RF output start and stop frequencies and amplitudes, a number of equally spaced points (steps) to dwell upon, and the

Seite 27

8Instruction Note1. Press [Preset].2. Press [Sweep/List]. This opens a menu of sweep softkeys.3. Press {Sweep Repeat Single Cont}. This toggles the sw

Seite 28 - Warranty

9Instruction NotePress {Sweep Repeat Single Cont}. This toggles the sweep from single to continuous. The SWEEP annunciator is activated indicating tha