5
cdma2000/1xEV-DO
Modulated Power Measurement
Range: −53 to +36 dBm; (−60 to +36 dBm)
1
Resolution: 0.1 dB
Accuracy: ≤ ±1.0 dB (25 ±5 °C), ≤ ±1.5 dB (0 to 50 °C)
Range: −60 to −53.01 dBm; (−70 to −60.01 dBm)
1
Resolution: 0.1 dB
Accuracy: ≤ ±1.5 dB (25 ±5 °C), ≤ ±2.0 dB (0 to 50 °C)
Frequency Error Measurement
Range: −10 to +10 kHz
Resolution: 0.1 Hz
Accuracy: ≤ ± (30 + reference signal) Hz,
Input level: −20 to +36 dBm;
(−30 to +36 dBm)
1
Origin Offset Measurement
Range: ≤ −20%
Resolution: 0.01%
Input level: −20 to +36 dBm
Time Offset Measurement
Range: −10 to +10 µSec
Resolution: 1/8 chip
Input level: −20 to +36 dBm
Access Probe Power Measurement
Resolution: 0.01%
Input level: −40 to +36 dBm
Code Power Measurement
Accuracy: ≤ ±2.0 (0 to 36 dBm), ≤ ±4.0 (−20 to −0.01 dBm)
Resolution: 0.1 dB
Input level: −20 to +36 dBm
1
Requires N9360AU-100 hardware installed in unit
RF Signal Generator for GSM/GPRS/EGPRS
Frequency step (MODEM): 0.1 kHz (Range: carrier < ±200 kHz)
Modulation:
GMSK (B.T=0.3), 8PSK, OFF (CW)
Output power accuracy
≤ ±1 −110.0 to −50.0 dBm (25 ±5 °C)
≤ ±1.5 dB −50.0 to −20.0 dBm (25 ±5 °C)
≤ ±1.5 −110.0 to −50.0 dBm (0 to 50 °C)
≤ ±2.0 dB −50.0 to −20.0 dBm (0 to 50 °C)
Output power accuracy
1
≤ ±1 −120.0 to −50.0 (25 ±5 °C)
≤ ±1.5 dB −50.0 to −10.0 dBm (25 ±5 °C)
≤ ±1.5 −120.0 to −50.0 dBm (0 to 50 °C)
≤ ±2.0 dB −50.0 to −10.0 dBm (0 to 50 °C)
Phase error (GMSK: ≤ 5 deg. RMS, ≤ 15 deg. Peak
(≤ 3 deg. RMS, ≤ 9 deg. Peak)
1
Modulation accuracy (8PSK): ≤ 12.5 % RMS; (≤ 7.0 % RMS)
1
Power level step: 0.1 dB
Power level range
Auto/Man: −110.0 to −50.0 dBm in 0.1 dB steps
(−120.0 to −50.0 dBm in 0.1 dB steps)
1
Tx analyzer: −110.0 to −50.0 dBm in 0.1 dB steps
(−120.0 to −50.0 dBm in 0.1 dB steps)
1
SG: −110.0 to −20.0 dBm in 0.1 dB steps
(−120.0 to −10.0 dBm in 0.1 dB steps)
1
Off: < −120 dBm; (−130 dBm)
1
Kommentare zu diesen Handbüchern