Agilent Technologies E6392B Betriebsanweisung Seite 153

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 206
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 152
152 Chapter 3
Screen Reference
CONFIGURATION
RX Quality
Accepts a set of high and low limits. The allowable choices are 0
(<0.2%), 1 (0.2 to 0.4%), 2 (0.4 to 0.8%), ....., 6 (6.4 to 12.8%),
and 7 (>12.8%). This is not effective for the Test Set installed with
Option 040.
RX Level
Accepts a set of high and low limits. The allowable choices are 0
(<110 dBm), 1 (110 to 109 dBm), 2 (109 to 108 dBm), ....,
62 (49 to 48 dBm) and 63 (>48 dBm). This is not effective for
the Test Set installed with Option 040.
DC Current
Accepts a set of high and low limits at Camp On and Talk. The
allowable range is from 3 to 1000 mA in 1 mA steps.
Test Item Description
Seitenansicht 152
1 2 ... 148 149 150 151 152 153 154 155 156 157 158 ... 205 206

Kommentare zu diesen Handbüchern

Keine Kommentare