15-14
DSP Analyzer Commands (Measure Subsystem)
SSTatus
SSTatus
Description Queries the Sync STatus for the current DSP measurement.
Syntax MEASure:DSPanalyzer:SSTatus?
Options Returns one of the following states;
’No Error’ | ’ShortBurst’ | ’Level Late’ | ’LevelShort’ |
’FM Error’ | ’Low Level’ | ‘Math Error’ | ’RF Ovrload’.
The message return priority (highest to lowest) is as follows:
Math Error
RF Ovrload | Low Level
FM Error
ShortBurst | Level Late | LevelShort
No Error
The above defined as;
ShortBurst - amplitude envelope not long enough for the selected burst length.
RF Ovrload - the DSP Analyzer sampler hardware overloaded during sampling.
FM Error - at least one FM error was detected during the Midamble (or User Defined
Sync Pattern) portion of the selected burst (only possible for MSYN:SYNC:MODE
’MIDAMBLE’)
Level Late - amplitude of the burst did not rise until after the first few bits were
received.
Level Short - amplitude of the burst fell before the last few bits were received.
Low Level - DSP Analyzer RF level never got high enough to make a valid
measurement.
Math Error - DSP Analyzer math-related error occurred.
No Error - no error occurred in synchronizing to the selected burst.