SCPI Commands Appendix C
Model N6705A User’s Guide 135
SCPI Command Description
MEASure
[:SCALar]
:CURRent [:DC]? (@chanlist) Takes a measurement; returns the average output current
:VOLTage [:DC]? (@chanlist) Takes a measurement; returns the average output voltage
:ARRay (ARRay commands only on N6761A/62A and Opt. 054)
:CURRent [:DC]? (@chanlist) Takes a measurement; returns the instantaneous output current
:VOLTage [:DC]? (@chanlist) Takes a measurement; returns the instantaneous output voltage
MMEMory (MMEMory commands only on N6705A)
:ATTRibute? “object”, “attribute” Gets the attributes of a file system object
:DATA[:DEFinite]? “filename” Gets the file contents; response is a definite length binary block
:DELete “filename” Deletes a file
:EXPort:DLOG “filename” Exports a data log from the display to a file
OUTPut
[:STATe] <Bool> [,NORelay], (@chanlist) Enables/disables the specified output channel(s)
:COUPle
[:STATe] <Bool> Enables/disables channel coupling for output synchronization
:CHANNel [<NR1> {,<NR1>}] Selects which channels are coupled
:DOFFset <NRf> Specifies a maximum delay offset to synchronize output changes
:MODE AUTO | MANual Specifies the output delay coupling mode (only on N6705A)
:MAX:DOFFset? Returns the maximum delay offset required for a mainframe
:DELay
:FALL <NRf+>, (@chanlist) Sets the output turn-off sequence delay
:RISE <NRf+>, (@chanlist) Sets the output turn-on sequence delay
:PMODe VOLTage | CURRent, (@chanlist) Sets the mode for turn on/off transitions (only on N6761A/62A)
:INHibit:MODE LATChing | LIVE | OFF Sets the remote inhibit input
:PON:STATe RST | RCL0 Programs the power-on state
:PROTection
:CLEar (@chanlist) Resets latched protection
:COUPle <Bool> Enables/disables channel coupling for protection faults
:DELay <NRf+>, (@chanlist) Sets over-current protection programming delay
:RELay:POLarity NORMal | REVerse, (@chanlist) Sets the output relay polarity (only on Opt. 760)
SENSe
:CURRent
[:DC]:RANGe [:UPPer] <NRf+>, (@chanlist) Selects the current measurement range (only on N6761A/62A)
CCOMpensate <Bool>, (@chanlist) Enables/disables the capacitive current compensation
:DLOG (DLOG commands only on N6705A)
:FUNCtion
:CURRent <Bool>, (@chanlist) Enables/disables current data logging
:MINMax <Bool> Enables/disables min/max data logging
:VOLTage <Bool>, (@chanlist) Enables/disables voltage data logging
:OFFSet <NR1> Sets trigger offset as a percent from start of data log duration
:TIME <NRf+> Sets the duration of the data log in seconds
:TINTerval <NRf+> Sets the time interval between data log samples
:FUNCtion “VOLTage” | ”CURRent”, (@chanlist) Selects the measurement function
:SWEep (SWEep commands only on N6761A/62A and Opt. 054)
:OFFSet:POINts <NRf+>, (@chanlist) Defines the trigger offset in the measurement sweep
:POINts <NRf+>, (@chanlist) Defines the number of data points in the measurement
:TINTerval <NRf+>, (@chanlist) Sets the measurement sample interval
:VOLTage[:DC]:RANGe [:UPPer] <NRf+>, (@chanlist) Selects the voltage measurement range (only on N6761A/62A)
:WINDow [:TYPE] HANNing | RECTangular, (@chanlist) Selects the window type (only on N6761A/62A and Opt. 054)