For LIN 1.3, the checksum appears in blue if correct, or red if incorrect. The checksum
always appears in white for LIN 2.0.
Decoded text is truncated at the end of the associated frame when there is insufficient
space within frame boundaries.
Red dots in the decode line indicate that there is data that is not being displayed.
Scroll or expand the horizontal scale to view the information.
Unknown bus values (undefined or error conditions) are drawn in red.
If there is an error in the synch field, SYNC will appear in red.
If the header exceeds the length specified in the standard, THM will appear red.
If the total frame count exceeds the length specified in the standard, TFM will appear
red (LIN 1.3 only).
For LIN 1.3 a wakeup signal is indicated by WAKE in blue. If the wakeup signal is not
followed by a valid wakeup delimiter a wakeup error is detected and displayed as WUP
in red.