Connecting Instruments to LAN 5
Agilent Connectivity Guide 121
Connect timeout. The time, in milliseconds, that the PC will wait
when attempting to connect to a LAN instrument. Default value: 5000
milliseconds
LAN maximum timeout: The actual timeout value used when a test
program specifies a timeout value of infinity. Default value: 120
seconds
Client delta timeout. The incremental time that is added to the timeout
value specified in a test program to allow for the additional time
required to transfer information over a LAN connection. Default value:
25 seconds
SICL interface ID. The unique name that SICL programs use to identify
this interface.
Logical unit. A number used to uniquely identify an interface in
Agilent VEE and SICL applications. The logical unit number is an
integer in the range of 0-99.
Log LAN connect errors. You can set Connection Expert to log LAN
connection error information in your Windows Event Viewer or Event
Log. Default setting: Yes
Auto-discover. Auto-discover is not shown in the Change Properties
dialog box, because it is required to be Off (No) for a LAN interface.
NOTE
The logical unit may be used in place of the SICL interface ID in
Agilent VEE and SICL applications. The logical unit is not used by
VISA.