Retrieving and Restoring Data Using the LAN
Retrieving and Restoring Data Using the LAN
To copy status information from \status
1 Access the logic analyzer's file system.
Refer to the chapter "Accessing the Logic Analyzer File System".
2 Copy the appropriate file from the \status directory.
The \status directory contains the following ASCII files:
system.txt - shows whether the analyzer is running or stopped. It also
includes information about the Group Run and the relative trigger times of
each module if applicable.
frame.txt - shows what is mapped to each slot and the operating system
version.
mount.txt - lists all connections to the logic analyzer. The connection
information includes the IP address and user type. This information is also
available in the External I/O LAN Settings menu, under Show LAN
Connections.
Example
An example system.txt file:
Analyzer name: LP LAN Analyzer
Execution Status:
slot_a - stopped