Agilent Technologies DisplayPort Wartungshandbuch Seite 123

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 152
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 122
Source AC Common Mode Noise Tests 13
U7232A DisplayPort Compliance Testing Notes 123
Figure 46 shows a physical connection for making single- ended
connections.
2641A
.
You can use any of the oscilloscope channel and connect them to any of
the lane test points. You select the channels used for test a lane in the Set
Up tab of the DisplayPort Electrical Performance Compliance Test
Application.
The data lanes and channels shown in the previous figures are just
examples. You can choose any desired data lane and channel that you
want.
Infiniium Oscilloscope
Data Channel
SMA to SMP cables
DUT
Lane on the W2641A test fixture
Figure 46 Probing for Single-ended Tests - AC Common Mode Noise Tests (Two
Connections with W2641A DisplayPort Test Fixture)