$JLOHQW0$996HULHV6HUYLFH*XLGH
)URQW+RXVLQJ$VVHPEO\9&9&9&79&7
Front Housing Assembly
V24C/V26C & V24CT/
V26CT
Version 2: Assembly Procedure for Display Options 026 to 029
less than PDC 3927
5HPRYLQJWKH%RDUG6KLHOG
Remove the Front Housing Assembly (see "Removing the Front Housing Assembly" on
page 9-2).
Remove the two screws located in the narrow channel and the two hex stand-off screws
securing the Board Shield and Flat Panel Bracket to the top of the Front Housing.
Remove the 4 hex nuts (5.5mm) securing the rest of the Board Shield to the Flat Panel
Bracket.
Lift Board Shield up and away from the Flat Panel Bracket.