Agilent E6432A Microwave Synthesizer Users Guide 4-105
HPE6432_GetQCal
ViStatus HPE6432_GetQCal (ViSession instrumentHandle,
ViUInt16 *qCalLevel);
Purpose
This function gets the level of the calibration voltage used for the Q
input when Test Tone is selected as the I/Q Input.
Parameter List
instrumentHandle
Variable Type ViSession
This is the ViSession handle that is obtained from the Initialize
function. The instrumentHandle identifies a particular instrument
session.
qCalLevel
Variable Type ViUInt16 (passed by reference)
This parameter returns the Test Tone calibration voltage for the Q
input.
Return Value
This parameter reports the return status of this function.
To obtain further information about the status that is returned, call the
Error Message function or refer to “Error-Code and Fail-Code
Messages” on page 3-93.
Related Topics
HPE6432_SetQCal