Chapter 5: Installing Pattern Generator Measurement Modules
16720A Pattern Generator (4-card module)
16720A Pattern Generator (4-card module)
NOTE: Turn off the mainframe power before removing, replacing, or installing
modules following the procedures on page 42.
1 Carefully slide the 4 cards half way into the mainframe slots.
2 Use four 2 x 10 cables to connect the modules. Cable the bottom
Expander Card to the Master Card first. Then cable the upper two
Expander Cards to the Master Card.
3 Gently slide the cabled assembly fully into the frame and tighten the
thumb screws.
Expander
Expander
Master
Expander
2x10
C
able
Seitenansicht 93