Agilent Technologies 16700 SERIES LOGIC ANALYSIS SYSTEM 16700 Installationsanleitung Seite 91

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 150
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 90
91
Chapter 5: Installing Pattern Generator Measurement Modules
16522A Pattern Generator (5-card module)
16522A Pattern Generator (5-card module)
NOTE: Turn off the mainframe power before removing, replacing, or installing
modules following the procedures on page 42.
1 Carefully slide the 4 cards half way into the mainframe slots.
2 Use five 2 x 10 cables to connect the modules. Cable the bottom
Expander Card to the Master Card first. Then cable the upper two
Expander Cards to the Master Card.
3 Gently slide the cabled assembly fully into the frame and tighten the
thumb screws.
Expander
Expander
Master
Expander
Expander
2x10
C
able
Seitenansicht 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 149 150

Kommentare zu diesen Handbüchern

Keine Kommentare