Load Monitor
Statistics: ATM
5967–9446 329
✓✓
In Frames
Out Frame
The total number of frames seen originating
from either direction of the link including
errored frames.
✓✓
In Octets
Out Octets
The sum of octets from all frames seen origi-
nating from either direction of the link includ-
ing errored frames.
✓✓
In Utilization
Out Utilization
Amount of bandwidth taken by traffic from
both directions of the link. This value is calcu-
lated by dividing in octets by the media speed.
✓✓
Total Errors Calculated by summing out of frame defects,
line coding violations, P-bit coding violations,
C-bit coding violations, remote alarm indica-
tion failures, alarm indication failures, loss of
frame failures, and loss of signal failures.
✓✓
In FECNs
Out FECNs
Number of frames for each direction, with the
Forward Explicit Congestion Notification bit
set.
✓✓
In DEs
Out DEs
Number of frames for each direction, with the
Discard Eligibility bit set.
✓✓
In BECNs
Out BECNs
Number of frames for each direction, with the
Backward Explicit Congestion Notification bit
set.
✓✓
Estimated Up Time
Estimated Down
Time
The estimated up or down time of this PVC,
based on monitoring PVC activity and LMI sta-
tus messages. May not equal the interval dura-
tion; the probe was unsure of the state in the
unaccounted for time.
Table 36 Load Monitor Statistics: DS3/E3, continued
Fr. Relay.
FR PVC
PPP
Statistic Description