Agilent Technologies 8753ET Betriebsanweisung Seite 269

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 546
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 268
Chapter 1 1-255
Alphabetical Command Reference
SWE
SWE
Syntax
SWEA;
SWET<num>[S]; or SWET?;
Description
NOTE The SWET command should be followed by a wait equal to 2 sweeps. Example
wait code written in BASIC:
10 OUTPUT 716;"SWET.1;"
20 WAIT 2*.1
Front Panel Equivalents
Command Description Range Query Response
SWEA Automatically selects the fastest sweep
time based on the current analyzer
settings for number of points, IF
bandwidth, sweep mode, averaging
condition and frequency span.
N/A N/A
SWET Sets the sweep time. (Setting SWET0 is
equivalent to sending the
SWEA
command.)
0–86,400 s
<num><
L
F
>
Command Hardkey Softkey
SWEA
SWET
Sweep Setup
SWEEP TIME AUTO
Sweep Setup
SWEEP TIME MANUAL
Seitenansicht 268