Agilent Technologies N9340A Betriebsanweisung Seite 129

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 174
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 128
Key Reference 5
N9340B User’s Guide 123
The mak types for IBOC- FM are listed as below:
FCC (FM- 73.317)
NRSC- 5- B Hybrid
NRSC- 5- B Hybrid
Figure 5-31 IBOC (FM) spectral emission mask and limits
-600 -400 -2 00 0 200 40 0 600
-110
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
Offset from c arrier frequency (kHz)
Level relative to unmodulated carrier(dBc)
IBOC (FM) spec tral emi ssion mask and li mit s
Trac e i n red is FCC spectral emissions mask.
Trac e i n blue is NRSC hybrid spectral emissions limits.
Trace in Black is NRSC all digital spectral emissions limits.
•Mask On/Off
Mask On/Off is a switch to enable the mask
function.
Set Span and RBW according to mask
standard automatically.
Set Average Type to Power and Detector to
Average (RMS), and also set average on with
average times to meet the measurement
specification.
Pass/Fail
Pass/Fail On/Off is a switch to enable/disable
PASS/FAIL verification.
Seitenansicht 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 173 174

Kommentare zu diesen Handbüchern

Keine Kommentare