Instructions Keystrokes
On the P-Series:
1. Select the WiMAX predefi ned
preset value.
[Preset], press [
or ] key to
choose {WiMAX}. [Select], {Confi rm}.
2. Set the trace display. [Disp], {Disp Type}, {Trace}.
3. Set the trigger holdoff 4 ms. [Trig/Acq], {Settings}, {1 of 2}, {Hold-
off 4 ms}.
4. Expand the window. Change the
scale. Move the marker to
measure 5 ms waveform duration.
Once the complete waveform on
the screen within 5 ms markers
1 and 2, stop the triggering
(See Figure 22).
[ ], {Trace Control}, {X Start
–400 µs, X Scale 600 µs & Y Scale
10 dB}, {Gate Control}. Press [
] to allocate marker 2 and [ ] to
allocate marker 1 within 5 ms time
duration. [Run/Stop]
Measuring both Downlink &
Uplink Waveform
The Signal Studio under Downlink step
reveals that the frame duration of
5 ms (see Figure 23). Moving the
cursor around the frame zone reveals
the time duration and power level of
the Preamble, DL, TTG, UL & RTG as
shown below:
• Preamble = 0.104 ms / 1 sym
• DL = 2.06 ms / 20 sym(s)
• TTG = 0.34 ms
* UL = 1.53 ms / 15 sym(s)
• RTG = 0.957 ms
Preamble region shows 0 dB. In DL
zone there are 3 different power levels:
i) –3.98 dB when the FCH and Burst 1
is one (just after the Preamble)
ii) –4.46dB when only Burst 1 is ON
ii) –10.27dB from the end of burst 1 to
the end of the zone. (Same as DL
waveform setup)
The UL zone shows two different
power levels:
i) –4.45 dB when only burst 1 is ON
ii) –4.58 dB from the end of burst 1 to
the end of the UL zone.
Figure 22 WiMAX waveform duration of 5ms for both DL &UL in
TDD mode
Figure 23 Frame duration (5 ms) of both DL & UL waveform captured from Signal Studio