72 Agilent E1330B Digital I/O Module Command Reference
Chapter 5
[SOURce:] Subsystem
The [SOURce:] subsystem defines the command set for the Digital I/O module
output statements. It also defines the state and polarity of the control line (CTL), the
polarity of the flag line (FLG), the handshaking mode, and handshake delay for both
data input and output. The root command,
[SOURce:], is optional.
[SOURce:]
DIGital
:CONTrol
n
:POLarity <POS|NEG>
:POLarity?
[:VALue] <0|1
or ON|OFF>
[:VALue]?
:DATAn
[:BYTE]
:BIT
m <0|1>
:BIT
m?
:HANDshake
:DELay <
time>
:DELay?
[:MODE] <NONE|LEADing|TRAiling
|PULSe|PARTial|STRobe>
[:MODE]?
:POLarity <POS|NEG>
:POLarity?
:TRACe <
name>
[:VALue] [<
base>]<value>
[:VALue]?
:LWORd
:BIT
m <0|1>
:BIT
m?
:HANDshake
:DELay <
time>
:DELay?
[:MODE] <NONE|LEADing|TRAiling
|PULSe|PARTial|STRobe>
[:MODE]?
:POLarity <POS|NEG>
:POLarity?
:TRACe <
name>
[:VALue] [<
base>]<value>
[:VALue]?
Seitenansicht 73