Agilent Technologies E1330B Bedienungsanleitung Seite 112

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 156
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 111
110 Agilent E1330B Digital I/O Module Register Information
Appendix B
The module is a register-based slave/interrupter device, supporting VME
D16, D8(O), and D8(OE) transfers. The interrupt protocol supported is
“release on interrupt acknowledge” – an interrupt is cleared by a VXIbus
interrupt acknowledge cycle.
WARNING Registers have been documented as 8 bit bytes. If you access
them using 16 bit transfers from a Motorola CPU, the high and
low byte will be swapped. The Agilent E1300/01 Mainframe and
Agilent E1405/06 Command Modules use Motorola CPUs.
Motorola CPUs place the highest weighted byte in the lower
memory location and the lower weighted byte in the higher
memory address; Intel processors do just the opposite. VXI
registers are memory mapped, thus you will see this
Motorola/Intel byte swap difference when doing register
programming.
Seitenansicht 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 155 156

Kommentare zu diesen Handbüchern

Keine Kommentare