Page 8 Development Flow for the Agilent 3070 Tester Without the PLD ISP Software
Using the Agilent 3070 Tester for In-System Programming in Altera CPLDs December 2010 Altera Corporation
Ensure that the actual vectors match the expected values for the input pins (TCK,
TMS, and TDI). If they are not the same, recompile the tests.
Ensure that the .pcf file order statement in the test matches the order of the .pcf file
code generated in “Step 2: Create a .svf File” on page 4. If they do not match,
change the order and recompile the tests.
If possible, verify that the device is programmed correctly with the Quartus II
software, the ByteBlaster
TM
II download cable, and the .pof file that you used to
generate the .svf file. This action is not practical in a production situation, but is
useful during test development and debugging.
If you need to isolate an individual device, generate an individual .svf file for each
targeted Altera device in the chain (refer to “Step 2: Create a .svf File” on page 4).
Use this process when a verification error occurs and you have programmed more
than one Altera device in the chain.
If the device fails to program, review the boundary-scan chain definition. Ensure
that the number of bits for the instruction register are correctly specified for each
device in the chain. If you defined an incorrect number of bits for any device in the
chain, the programming test fails.
After the test is running correctly, the board is ready for production programming.
Altera recommends saving the .pcf files and object code for back-up purposes. To
minimize the size of the stored binaries and files, use a compression program.