Agilent-technologies Wireless Network Optimization Platform E6474A Bedienungsanleitung Seite 125

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 194
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 124
Getting Assistance, If You Need It 6
Agilent E6474A User’s Guide 125
Setting an iDEN phone’s baud rate
The baud rate for any iDEN phone must be set to 19200
baud, otherwise the phone may not be identified (this
applies to serial connections only). The following is the
procedure for the i1000 Plus phone.
1 Power up the phone. Wait forPhone Ready to be
displayed.
2 Press the Menu key 3 times.
3 Press the key under Prgm shown in the display. The
Programming Menu is displayed.
4 Press the key under OK in the display.
5 Press the right arrow key until Set Baud Rate: <value> is
displayed.
6 Press the key under OK in the display.
7 Press the right arrow key until 19200 is displayed.
8 Press the key under OK in the display.
9 Press the key under Exit in the display.
Toshiba phone power-up issues
Toshiba direct-connect phone power-up
Toshiba JCDMA phones have special power- up procedures.
Each time you power up the system, you must perform the
following procedure to enable communication between the
phone and the data collection software. Begin all of the
following procedures with the phone and computer powered
off.
Toshib a 1 0-CT
1 Unplug the phone interface cable from the phone.
2 Power the computer on.
3 Power the phone on.
4 Plug the interface cable into the phone.