Agilent-technologies N2620A Bedienungsanleitung Seite 147

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 279
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 146
DSL Testing with the FrameScope Pro 5
N2620A User’s Guide 129
Advance screen to access Modem Network Settings and Te st
Settings. Refer to “Advanced Settings for VIT-A2” on page 135 for
further details.
If you agree to activate the settings in the VIT-A2, the
FrameScope Pro overwrites the VIT-A2 settings with the test
suite settings. These settings will then be activated in the
VIT-A2.
If you disagree to activate the settings in the VIT-A2, the
VIT-A2 settings are not overwritten. The test suite settings
are still shown on the FrameScope Pro but are not activated
in the VIT-A2.
Press Commit to manually activate these settings.
Press Cancel to read the settings from the VIT-A2.
When the connection is established with the VIT-A2, the
FrameScope Pro displays the following parameters.
The upstream and downstream connection parameters
Noise Mrgn: SNR margin (dB)
Attenuation: Line attenuation (dB)
Seitenansicht 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 278 279

Kommentare zu diesen Handbüchern

Keine Kommentare