Specifications describe the instrument’s
warranted performance over the
temperature range of 0 °C to 40 °C
(except as noted). Supplemental
characteristics are intended to provide
information that is useful in applying
the instrument by giving non-warranted
performance parameters. These are
denoted as typical, typically, nominal,
or approximate. Warm-up time must
be greater than or equal to 30 minutes
after power on for all specifications.
Agilent
4396B 1.8 GHz
Network/Spectrum/Impedance Analyzer
Data Sheet
Network Measurement
Source characteristics
Frequency characteristics (Option 4396B-800)
Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 kHz to 1.8 GHz
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mHz
Frequency reference
Accuracy
23 ±5 °C, referenced to 23 °C . . . . . . . . . . . . . . . . . . .< ±5.5 ppm/year
Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .< ±2.5 ppm/year typically
Initial achievable accuracy . . . . . . . . . . . . . . . . . . . . . . .< ±1.0 ppm typically
Temperature stability
23 ±5 °C, referenced to 23 °C . . . . . . . . . . . . . . . . . .< ±2 ppm typically
Precision frequency reference (Option 4396B-1D5)
Accuracy
0 °C to 40 °C, referenced to 23 °C . . . . . . . . . . . . . . .< ±0.13 ppm/year
Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .< ±0.1 ppm/year typically
Initial achievable accuracy . . . . . . . . . . . . . . . . . . . . . .< ±0.02 ppm typically
Temperature stability
0 °C to 40 °C, referenced to 23 °C . . . . . . . . . . . .< ±0.01 ppm typically
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - 4396B 1.8 GHz

Specifications describe the instrument’swarranted performance over the temperature range of 0 °C to 40 °C(except as noted). Supplemental characteristi

Seite 2 - Output Characteristics

10Typical Dynamic RangeFigure 6. Typical dynamic range at S inputFigure 7. Typical dynamic range at R, A, and B inputsDynamic range (dB)Input level (d

Seite 3 - Receiver Characteristics

11Spurious responsesSecond harmonic distortion≥ 10 MHz, –35 dBm mixer input . . . . . . . . . . . . . . . . . . . . . . . . .< –70 dBc< 10 MHz

Seite 4 - Input level (dB)

12Frequency response2 ±5 °C, aft. = 10 dB, referenced to level at 20 MHz10 MHz ≤ frequency ≤ 1.8 GHz . . . . . . . . . . . .< ±0.5 dB (±0.3 dB typ

Seite 5 - Phase Characteristics

13Sweep characteristicsSweep type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Linear, zero span, listTrigger type . . . .

Seite 6 - Aperture (Hz)

14Input and Output CharacteristicsRF inputConnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Type-N femaleImped

Seite 7 - Frequency Characteristics

15Specifications when Option 4396B-1D6 time-gated spectrum analysis is installedGate lengthRange . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 8 - Carrier frequency = 1 GHz

16Impedance Measurement (Option 4396B-010)Measurement functionsMeasurement parameters . . . . . . . . . . . . . . . . . . . . . . .Z, Y, L, C, Q, R,

Seite 9 - Offset frequency (Hz)

17External DC bias input1Maximum voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±40 VMaximum current

Seite 10 - Input level (dBm)

18IZI – θ accuracyIZI accuracy Za= A + (B/IZmI + C x IZmI) x 100[%]θ accuracy θa= sin–1(Za/100)Where, is IZmI is IZI measured. A, B, and C are obtai

Seite 11 - Input attenuator = 0 dB

19IYI – θ accuracyIYI accuracy Ya= A + (B x IYmI + C/IYmI ) x 100[%]θ accuracy θa= sin–1(Ya/100)Where, IYmI is IYI measured. A, B, and C are obtained

Seite 12

2Output CharacteristicsPower range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–60 dBm to +20 dBm Power sweep range .

Seite 13

20D accuracyAccuracy D ≤ 0.2 0.2 < DDaza/100 (za/100) x (1 + D2)Where Zais IZI accuracy.L accuracy (depends on D)Accuracy D ≤ 0.2 0.2 < DLaLa/10

Seite 14

21Common Specifications for Network and Spectrum MeasurementDisplayTFT LCDSize/type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 15

22Probe powerOutput voltage . . . . . . . . . . . . +15 V (300 mA), –12.6 V (160 mA), GND nominalKeyboardConnector . . . . . . . . . . . . . . . . . .

Seite 16

232nd IF outputFrequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21.42 MHz nominaloutput impedance . . . . . . .

Seite 17

24S-parameter test set interfaceConnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-SUB (25 pin)External m

Seite 18

25OthersEMC1. . . . . Complies with CISPR 11(1990) / EN 55011 (1991): Group 1, Class AComplies with IEC 801-2 (1991) / EN 50082-1 (1992): 4 kV CD, 8

Seite 21

Agilent Technologies’ Test and Measurement Support, Services, and AssistanceAgilent Technologies aims to maximize the value you receive, while minimiz

Seite 22 - General Characteristics

3Receiver CharacteristicsInput characteristicsFrequency rangeIFBW ≤ 3 kHz . . . . . . . . . . . . . . . . . . . . . . . . .100 kHz to 1.8 GHzIFBW = 1

Seite 23 - Negative trigger signal

4Magnitude CharacteristicsAbsolute amplitude accuracy (R, A, B)–20 dBm input, 23 ±5 °C . . . . . . . . . . . . . . .< ±1.5 dB (±0.9 dB typically)R

Seite 24 - Non-Operation Conditions

5Phase CharacteristicsMeasurements format . . . . . . . . . . . . . . .Phase format, expanded phase format Frequency response (deviation from linear

Seite 25

6Group Delay CharacteristicsAccuracyIn general, the following formula can be used to determine the accuracy, in seconds, of a specific group delay m

Seite 26

7Spectrum MeasurementSpecifications in this section describe the instrument’s warranted performancefor spectrum measurement using S input (except as n

Seite 27

8Noise sidebandsOffset from carrier Noise sidebands1≥ 1 kHz < –95 dBc/Hz≥ 10 kHz < –105 dBc/Hz≥ 1 MHz < –110 dBc/HzResidual FMRBW ≤ 10 HzOpti

Seite 28 - Agilent Email Updates

9On-screen dynamic range1 GHz center frequency, may be limited by average noise level.Amplitude characteristicsAmplitude range . . . . . . . . . . . .