At-a-Glance Confidence in Operation
The front panel indicator lights on the E8401A VXI mainframe
gives immediate visual indication that the power supply
voltages are operating within the VXI Specification, the
temperatures are within limit, and that the fans are
operational. Backplane activity and SYSFAIL indicators are
also provided.
The system can be reset easily from the front panel, providing
reset even when the Slot 0 is inaccessible due to cabling.
The diagnostic connector, conveniently located on the front
of the mainframe, provides connection for remote monitoring
of power supply voltages, power supply and reference
temperatures, and fans function. This connector also allows
remote on/standby, access to +5VSTDBY, ACFAIL, and
SYSRESET. The connector’s functionality is a superset of the
functionality on the E1401B Mainframe, allowing software and
hardware compatibility with existing applications. Up to 1A of
+5VSTDBY may be provided by the user through the
connector. Up to 1A each of + 5V and + 12V are available for
external applications through the connector.
Improved, Highly Reliable Backplane Design
The backplane features solid state automatic daisy-chain
jumpering for the VMEbus grant and interrupt acknowledge
lines, eliminating the need for hand selection of switch
settings. Full differential distribution of the CLK10 signal is
provided on the backplane. This minimizes jitter and skew,
providing a clean timing source for VXI instrument modules.
The surface mount backplane improves both reliability and
stripline signal performance.
Agilent generates SYSRESET and ACFAIL on the backplane.
This is necessary for full compliance with the VXI
Specification, but is not generally implemented by other
manufacturers.
Easy Maintenance Rear-Accessible Power Supply and
Impeller
Convenient access to both the power supply and cooling
system is provided through the mainframe’s rear panel; a
replacement power supply or fan can be installed without
removing the mainframe from a rack. The power supply’s
plug-in design makes repairing easy.
The impeller for module cooling is easily replaced. The
internal fan for the power supply, an integral part of the
supply, is easily replaced with the power supply itself. If the
optional Air Filter Accessory Kit is installed, air filters may be
replaced without tools.
Accessories and Configurations
Optional Rack Mounting Kits
Three rack mounting kits are available for the mainframe,
providing versatile options for installation in an Agilent or a
non-Agilent rack. The following rack mounting kits are
available: Standard Adapter Kit, Flush Mount Adapter Kit and
VXI
plug&play
Compliant Adapter Kit.
Standard Adapter Kit for Recess, Flush or Forward Rack
Mounting
Using the Standard Adapter Kit (E8394A), the mainframe can
be recess mounted up to 10.6 inches in 1/2 inch increments.
(Recess mounting is required for compatibility with the tinted
acrylic door.) The mainframe can also be mounted extended
from the front of the rack from 0 to 5.8 inches in 1/2 inch
increments, allowing mounting in racks with shallow depths.
The Standard Adapter Kit includes handles and requires the
E3664A Support Rail Kit or the 1494-0411 Rack Slide Kit.
Flush Mount Adapter Kit
The Flush Mount Adapter Kit (Opt. 924 or E8400-80924), the
least expensive of the adapter kits, allows flush rack
mounting of the mainframe. It does not include handles. The
Flush Mount Adapter Kit requires the E3664A Support Rail
Kit. The Flush Mount Adapter Kit is not compatible with the
tinted acrylic door or with the rack slides.