USER’S GUIDEAgilent TechnologiesSeries 661xxAMPS POWER MODULES& Model 66001A MPS KEYBOARD Agilent Part No. 5959-3386

Seite 2 - ASSISTANCE

10 General InformationAccessoriesAgilent No. Description66002A Rack mount for Agilent 66001A MPS keyboardDescriptionThe Agilent 66lxxA Series

Seite 3 - SAFETY SUMMARY

General Information 11When the power module is operated beyond either rated output, the performance specifications are not guaranteed, althoughtypi

Seite 4 - Printing History

12 General InformationTable 1-1. Performance Specifications (continued)Agilent ModelParameter 66101A 66102A 66103A 66104A 66105A 66106ALine Regula

Seite 5 - DECLARATION OF CONFORMITY

General Information 13Table 1-2. Supplemental Characteristics (continued)Agilent ModelParameter 66101A 66102A 66103A 66104A 66105A 66106ATemperatu

Seite 6

14 General Information Table 1-2. Supplemental Characteristics (continued) Agilent Model Parameter 66101A 66102A 66103A 66104A 66105A 66106A Tri

Seite 7 - Table of Contents

General Information 15Table 1-2. Supplemental Characteristics (continued)Parameter Agilent Model Number and Paramete

Seite 9 - General Information

Installation 172InstallationInspectionDamageWhen you receive your power module, inspect it for any obvious damage that may have occurred during shi

Seite 10 - Description

18 InstallationFigure 2-1. Power Module Line Fuse and SwitchesFigure 2-2. Power Module Configuration SwitchTable 2-1. Settings for Power Module

Seite 11

Installation 19Remote Inhibit (RI) Function SwitchesThis function allows the power module outputs to be shut down from a signal (low-true TTL level

Seite 12

2CERTIFICATIONAgilent Technologies certifies that this product met its published specifications at time of shipment from the factory. AgilentTechnolog

Seite 13

20 InstallationInstalling The Module In The MainframeFigure 2-3. Power Module InstallationNote A fully loaded mainframe can weigh over 36 kg (80 l

Seite 14

Installation 21Output ConnectionsBefore making the actual connections, you must decide on the system configuration. The following factors are desc

Seite 15

22 Installation Remote Voltage Sensing Figure 2-4B shows the wiring for remote sensing. There is a switch on the output connector that selects ei

Seite 16

Installation 23Output RatingThe rated output voltage and current specified in Table 1-1 applies at the output terminals of the power module. Withr

Seite 17 - Installation

24 Installation5. In order to maintain proper regulation, the load must always draw at least as much current as is programmed for themodule that is

Seite 18

Installation 25Figure 2-6. Connecting Power Modules in SeriesEach power module has a reverse voltage protection diode across its output. If a rev

Seite 19

26 InstallationThe power module is designed to be stable for load capacitances up to the following values:Agilent 66101A 50,000 µF Agilent 66104

Seite 20 - Connecting The Load

Turn-On Checkout 273Turn-On CheckoutIntroductionThis chapter provides a quick test of the power module functions. See "Chapter 4 - Basic Powe

Seite 21

28 Turn-On CheckoutPower Module Turn-On StateWhen you turn on the mainframe, the power module goes through a self-test. All front panel readout di

Seite 22

Turn-On Checkout 29In Case Of TroubleMainframe FailureYou can assume there is a problem with the mainframe if there is more than one module in the

Seite 23

3 SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation of this power module. Failure to comply wi

Seite 24

30 Turn-On CheckoutSelftest Error MessagesTable 3-3 lists the displayed selftest error messages. All these errors are hardware failures that requi

Seite 25

Basic Power Module Commands 314Basic Power Module CommandsIntroduction"Chapter 3 - Language Dictionary" of the Programming Guide describe

Seite 26 - Connecting The Controller

32 Basic Power Module Commands Controlling the Output State The following commands control the power module output state: Table 4-1. Power Modu

Seite 27 - Turn-On Checkout

Basic Power Module Commands 33 Controlling List-Mode Output The following commands control the power module list-mode voltage and current output.

Seite 28 - Power Module Turn-On State

34 Basic Power Module Commands Using the RI/DFI Functions RI (Remote Inhibit) Input The signal applied to the mainframe digital connector INH in

Seite 29 - In Case Of Trouble

Calibration 35 A Calibration Introduction The power module may be calibrated either over the GPIB from a controller or from an Agilent 66001A Mo

Seite 30

36 Calibration Equipment Required The equipment listed in Table A-1, or equivalent, is required for calibration. Table A-1. Equipment Required

Seite 31 - Basic Power Module Commands

Calibration 37 Figure A-1. Calibration Test Setup Calibrating Current The following procedure calibrates the output current. During the calib

Seite 32

38 Calibration Using The CAL:AUTO Command Normal calibration procedures also calibrate the readback circuits that respond to the MEAS: CURR? and

Seite 33

Calibration 39 10 ! VOLTAGE CALIBRATION PROGRAM 20 ! CONNECT INSTRUMENTS AS SHOWN IN FIGURE A-la 30 ! 40 DIM Resp$[255],Err_msg$[255] 50 Volt_

Seite 34 - Changing The Power On State

4 SAFETY SYMBOL DEFINITIONS Symbol Description Symbol Description Direct current Terminal for Line conductor on permanently installed equipment A

Seite 35 - Calibration

40 Calibration 500 INPUT "ENTER VALUE OF CURRENT SHUNT BEING USED",Shunt_val 510 OUTPUT @Ps;"CAL:CURRENT:LEVEL MIN" 520 IN

Seite 36 - Calibrating Voltage

Agilent 66001A MPS Keyboard 41 B Using The Agilent 66001A MPS Keyboard Introduction This appendix describes the Agilent 66001A Modular Power S

Seite 37

42 Agilent 60001A MPS Keyboard Keyboard Description This section briefly explains the various areas on the keyboard as indicated in the followin

Seite 38 - Calibration Error Messages

Agilent 66001A MPS Keyboard 43 ô SYSTEM KEYS This key switches from remote operation (over the GPIB) to local operation using the keyboard.Pres

Seite 39

44 Agilent 60001A MPS Keyboard û ENTRY KEYS These keys let you enter numeric values. Values can be entered directly. If the Meter function is

Seite 40

Agilent 66001A MPS Keyboard 45 Using The Display Changing or Entering Values The following figure is an example of the keyboard display when a p

Seite 41 - Connecting The Keyboard

46 Agilent 60001A MPS Keyboard Sending SCPI Commands As described in the power module Programming Guide, SCPI commands are organized into message

Seite 42 - Keyboard Description

Agilent 66001A MPS Keyboard 47Press to execute the command.Using the letter keys to directly access and send commands is much faster than using t

Seite 43

48 Agilent 60001A MPS KeyboardThe query response remains on the display until you press another key to do something else, or until the module goes

Seite 44

Agilent 66001A MPS Keyboard 49If the Err annunciator is still on after the error message is displayed, it means there are additional error message

Seite 45 - Using The Display

5 DECLARATION OF CONFORMITY According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014 Manufacturer’s Name and Address Responsible Party Alternate Ma

Seite 46 - Sending SCPI Commands

50 Agilent 60001A MPS Keyboard

Seite 47

Index 51IndexAaddress slot, 20ampere capacity, 21annunciators, display panel Addr, 27 CC, 27 Dis, 27 Prot, 27 Unr, 27Ccabl

Seite 48

52 IndexIndex (continued) Lsn, 42 Prot, 42 Rmt, 42 Shift, 42 SRQ, 42 Tlk, 42 Unr, 42keyboard cursor, 45keyboard

Seite 49 - SCPI Command Tree

Index 53Index (continued)Rremote inhibit (see RI)RIdescription of , 10digital connector pins for (see Chapter 3 inInstallation Guide)examples of us

Seite 50

54 Agilent Sales and Support OfficeAgilent Sales and Support OfficesFor more information about Agilent Technologies test and measurement products,

Seite 51

Manual Updates The following updates have been made to this manual since the print revision indicated on the title page. 4/15/00 All references to

Seite 53

7Table of Contents1. General Information Introduction...

Seite 54

8Table of Contents (continued) Module Output Connector.......

Seite 55 - Manual Updates

General Information 91General InformationIntroductionThis guide describes how to install, check out, operate, and calibrate the Agilent Series 661x

Kommentare zu diesen Handbüchern

Keine Kommentare