Agilent Technologies
6000 Series Oscilloscopes
Data Sheet
MORE
The new Agilent 6000 Series oscilloscopes deliver more powerful features
and higher performance than any other scopes in their price range.
lab scope performance
at a
portable scope price
NEW
I
2
C/SPI,
CAN/LIN Bus
Decode Options
Available
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - 6000 Series Oscilloscopes

Agilent Technologies6000 Series OscilloscopesData SheetMOREThe new Agilent 6000 Series oscilloscopes deliver more powerful features and higher perform

Seite 2 - The performance and

10Agilent 6000 Series oscilloscopes: The right combination of featuresand performance to bring your toughest problems into focus.MegaZoom III deep mem

Seite 3 - Selection guide

11Quickly pan and zoom for analysis withMegaZoom III’s instant response and optimum resolution.QuickMeas shows up to four automatedmeasurements with t

Seite 4 - Selection guide (continued)

12ProbesTo get the most out of your scope,you need the right probes andaccessories for your particularapplication. That's why AgilentTechnologies

Seite 5 - Industry-leading performance

13ApplicationsN5406A FPGA dynamic probe for6000 Series MSOThe N5406A FPGA dynamicprobe for the 6000 Series MSOprovides the most effectivesolution for

Seite 6

14Applications (continued)N5423A I2C/SPI serial decode optionThe N5423A serial decode option for I2C and SPI busdisplays responsive, time-alignedon-sc

Seite 7 - Full-scale connectivity

15Performance characteristicsAcquisition: scope channels Sample rate MSO/DSO601xA/603xA: 2 GSa/sec each channelMSO/DSO605xA/610xA: 4 GSa/sec half chan

Seite 8 - Powerful triggering

16Performance characteristics (continued)Vertical system: scope channelsScope channels MSO/DSO6xx2A: Ch 1 and 2 simultaneous acquisitionMSO/DSO6xx4A:

Seite 9 - Other standard features

17Performance characteristics (continued)Vertical system: scope channels (continued)Noise peak-to-peak MSO/DSO601xA: 3% full scale or 2 mV, whichever

Seite 10 - Rear panel inputs/outputs

18Performance characteristics (continued)HorizontalRange MSO/DSO601xA: 5 nsec/div to 50 sec/divMSO/DSO603xA: 2 nsec/div to 50 sec/divMSO/DSO605xA: 1 n

Seite 11

19Performance characteristics (continued)Trigger system (continued)Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I2C,

Seite 12

2The performance andproblem-solving tools you need to meet your mixed analog anddigital design challenges, todayand tomorrow• A variety of models opti

Seite 13 - Applications

20Performance characteristics (continued)Scope channel triggeringRange (internal) ±6 div from center screenSensitivity* <10 mV/div: greater of 1 di

Seite 14 - Applications (continued)

21Performance characteristics (continued)Measurement featuresAutomatic measurements Measurements are continuously updated. Cursors track last selected

Seite 15 - Performance characteristics

22Performance characteristics (continued)General characteristicsPhysical size 35.4 cm wide x 18.8 cm high x 28.2 cm deep (without handle)39.9 cm wide

Seite 16 - (continued)

23Ordering informationModel number DescriptionDSO6012A 100 MHz 2-ch DSOMSO6012A 100 MHz 2+16-ch MSODSO6014A 100 MHz 4-ch DSOMSO6014A 100 MHz 4+16-ch M

Seite 17

24Ordering information (continued)Available options Option number Description MSO/DSO603xA MSO/DSO605xA MSO/DSO610xAOption 2ML 2 Mpts memory for √MSO

Seite 18

25Ordering information (continued)Accessories Product number Description1180CZ Testmobile scope cartN2916A Rackmount kit for 6000 Series scopeN2917A T

Seite 19

26Ordering information (continued)High-voltage probes Product number Description10076A 100:1, 4 kV, 250 MHz probe with IDN2771A 1000:1, 15 kV, 50 MHz

Seite 20

27Ordering information (continued)ApplicationsProduct number DescriptionN5406A FPGA dynamic probe for 6000 Series scope (One option listed below must

Seite 21

www.agilent.comAgilent Technologies’ Test and Measurement Support, Services, and AssistanceAgilent Technologies aims to maximize the value you receive

Seite 22

3Selection guideFigure 1. The 6000 Seriesfamily shown with 2+16-channel, 4+16-channelMSO and 2- and 4-channelDSO models.Agilent focuses on developing

Seite 23 - Ordering information

4Selection guide (continued)Easily see complex interactions with2+16-channel or 4+16-channel mixed signal oscilloscopes (models MSO6000A)The mixed sig

Seite 24

5Industry-leading performanceMegaZoom III deep memoryWith many of today’s designscontaining a mix of signal types and speeds, it’s oftencritical to ca

Seite 25

6Industry-leading performance (continued)Revolutionary high-definition colordisplay helps you see subtledetails that most scopes can’tshow youCombine

Seite 26

7Full-scale connectivityStandard USB, Ethernet/LAN andGPIB interfaces – choose the interfaceyou want to useThe 6000 Series scopes come with standard U

Seite 27

8Powerful triggeringFull-width pattern triggeringWith mixed analog and digitaldesigns, sometimes it’s hard totrace an anomaly back to its rootcause un

Seite 28 - Agilent Open

9Other standard features• Built-in help at your fingertipsAn innovative built-in helpsystem in six differentlanguages (English, Japanese,simplified Ch