Agilent E5500 A-Series
Preconfigured Solutions
The E5500 A-series solutions have
been configured to meet the needs of
production test. They include industry
standard VXI and MMS modular
hardware to provide maximum test
throughput, current and future meas-
urement flexibility, and asset reuse.
These solutions can easily include
specific RF reference sources, addi-
tional baseband analysis hardware,
and computers for complete production
phase noise measurement solutions.
E5501A 50 kHz to 1.6 GHz
E5502A 50 kHz to 6 GHz
E5503A 50 kHz to 18 GHz
E5504A 50 kHz to 26.5 GHz
The Agilent E5500 A-series solution
hardware includes:
0.01 Hz to 4 MHz VXI digitizer
VXI to PC high speed interface
6-slot, high power VXI mainframe
MMS baseband test set and frame
E5502/03/04A solutions add an MMS
low noise downconverter.
Optional Capabilities
Extend offset range to 8, 10, and
100 MHz
Add RF reference source
Add high power input capability
(includes µW phase and AM
detectors)
Add specific ATE computer
Extend carrier frequency to
110 GHz
Operating Characteristics
Offset frequency range:
0.01 Hz to 4 MHz
System noise response:
1
–180 dBc/Hz typically
(>10 kHz offsets)
System spurious response:
1
<–120 dBc typically
Phase detector input power:
(<1.6 GHz carrier frequency)
R input = 0 to +23 dBm
L input = +15 to +23 dBm
Downconverter input range:
1 GHz to 6 GHz
1 GHz to 18 GHz
1.5 GHz to 26.5 GHz
External noise input port:
0.01 Hz to 100 MHz
Measurement accuracy:
±2 dB (<1.0 MHz offsets)
±4 dB (<100 MHz offsets)
The Agilent E5503A configuration