Agilent Technologies N9360A Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
5
N9360A-034
W-CDMA
Modulated Power Measurement
Item Specification Unit
Input range -60 to +36 dBm
Resolution 0.01 dB
Resolution
for display
Open Loop
Inner Loop
MAX TX Power
PRACH Power
0.1
0.01
0.01
0.1
dB
Accuracy
MAX TX
Power
0 to +36 [dBm]
±0.7 (25 ± 5 deg C)
Typical = ±0.4
±1.0 (0 to 50 deg C)
dB
-53 to -0.01 [dBm]
±1.0 (25 ± 5 deg C)
Typical = ±0.5
±1.5 (0 to 50 deg C)
dB
-60 to -53.01 [dBm]
±1.5 (25 ± 5 deg C)
Typical = ±0.8
±2.0 (0 to 50 deg C)
dB
Inner Loop -20 to +36 [dBm]
1 dB ctrl: ± 0.2
10 dB ctrl: ± 0.5
dB
Frequency Error Measurement
Item Specification Unit
Range 0 to ±500 Hz
Resolution 0.1 Hz
Accuracy
± (10+Reference signal)
Hz
Input level -20 to +36 dBm
EVM Measurement
Item Specification Unit
Range 0 to 20 %
Resolution 0.01 %
Residual EVM
3.8
%
Input Level -20 to +36 dBm
ACLR Measurement
Item Specification Unit
Input level -5 to +36 dBm
Range 0 to -40 (@5 MHz)
0 to -48 (@10 MHz)
dB
Resolution 0.01 dB
OBW Measurement
Item Specification Unit
Input level -5 to +36 dBm
Accuracy < ±100 kHz
Range 0.00 to 9.99 MHz
Resolution 0.01 MHz
Sensitivity/BER
Item Specification Unit
Input level -20 to +36 dBm
Range PN9: 0.00 to 25.00
PN15: 0.00 to 33.33
%
RF Signal Generator
Item Specification Unit
Modulation W-CDMA: QPSK
Off: CW
Modulation accuracy
QPSK 12.5
%RMS
Output power Accuracy @-115.0 to –50.0 dBm
±1 (25 ±5 deg C)
±1.5 (0 to 50 deg C)
@-50.0 to –18.0 dBm
±1.5 (25 ±5 deg C)
±2.0 (0 to 50 deg C)
dB
dB
Frequency Band I 2110 to 2170 MHz
Band II 1930 to 1990
(1932.5, 1937.5, 1942.5,
1947.5, 1952.5, 1957.5,
1962.5, 1967.5, 1972.5,
1977.5, 1982.5, 1987.5)
Band III 1805 to 1880
Band IV 2110 to 2170
Band V 869 to 894
(871.5, 872.5, 876.5,877.5,
882.5, 887.5)
Band VI 875 to 885
(877.5, 882.5)
Power level step 0.1 dB
Power level range Mod
CW
Off
-115.0 to –18.0 [dBm] in 0.1
[dB] steps
-115.0 to –18.0 [dBm] in 0.1
[dB] steps
-120.0
dBm