systems.
Frequency Measurement
During AC/DC voltage or AC/DC current
measurements, you can measure the signal
frequency by pressing at any time.
Frequency Counter Measurement
1 Set the rotary switch to .
2 Press to select the frequency
counter (Hz) function. “—1—” on the
secondary display means the input signal
frequency is divided by 1. This
accommodates for higher frequency range
of up to 985 kHz.
3 Connect the red and black test leads to
input terminals V (red) and COM (black)
respectively.
4 Probe the test points and read the display.
5 If the reading is unstable or zero, press
to select division of input signal
frequency by 100. This accommodates a
higher frequency range of up to 20 MHz.
6 The signal is out of range if the reading is
still unstable after step 5.