Agilent Technologies N9320A Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Multimeter Agilent Technologies N9320A herunter. Agilent N9320A Spectrum Analyzer Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 12
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Agilent N9320A
Spectrum Analyzer
Technical Overview
All the essentials of an
Agilent spectrum analyzer
with a price/performance
that's easy to afford
N9320A Spectrum Analyzer
·9 kHz to 3 GHz range
·10 Hz to 1 MHz RBW
·148 dBm DANL with pre-amp
·
+13 dBm third-order intercept
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Spectrum Analyzer

Agilent N9320ASpectrum AnalyzerTechnical OverviewAll the essentials of an Agilent spectrum analyzerwith a price/performance that's easy to afford

Seite 2 - Low-cost

External trigger inputVGA output: Input amplitude: 5 V TTL levelConnector and ,latnoziroh zHk 5.13BGR golana AGV60 Hz vertical sync rates; non-interl

Seite 3

Ordering information11noitpircseDrebmun ledoMN9320ASpectrum analyzer 9 kHz to 3.0 GHzAccessories supplied as standard with each tester: · User's

Seite 4 - Bench repair

Agilent Technologies related product for manufacturing test, field maintenance and educationN9310A RF Signal GeneratorLow-cost signal generator coveri

Seite 5 - Education

Low-costmanufacturingNeeding faster and more cost effective RF analysis of today's consumer electronics devices and components?Maybe its low- or

Seite 6 - Specifications

Power measurements made easy using the measurement suiteOne of the most fundamental measurements performed by spectrum analyzers is the frequency-doma

Seite 7 - Amplitude

When it comes to receiving the best return from your R&D equipment budget, turn to Agilent's new generation of low-cost sources and analyzers

Seite 8

EducationUsing Agilent test equipment in your educational establishment guarantees you are upholding the highest standards for the future, for tomorro

Seite 9 - Front panel input/output

SpecificationsSpecifications apply under the following conditions:· After a warm-up time of 45 minutes,· At an ambient temperature specified in the da

Seite 10 - VGA output:

7Video bandwidth (VBW) Measurement rangeInput attenuator rangeMaximum damage level1 dB gain compressionDisplayed average noise levelLevel display rang

Seite 11 - Ordering information

Input attenuation switching uncertainty at 50 MHzAbsolute amplitude accuracyReference levelReference level accuracyLevel measurement uncertaintySpurio

Seite 12 - Remove all doubt

9Tracking generator source output (optional)10 MHz reference output10 MHz reference inputWarm-up: 45 minutesOutput frequency range: 100 kHz to3.0 GHz

Kommentare zu diesen Handbüchern

Keine Kommentare