Agilent Technologies N1911A Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
2
P-Series Power Meters
The P-Series power meters provide peak, average,
peak-to-average ratio, maximum and minimum
power measurements, time-gated and free-run
modes, rise time and fall time measurements, as
well as statistical information such as the comple-
mentary cumulative distribution function (CCDF).
PC analysis software (part number N1918A)
is available for complete pulse and statistical
analysis.
The P-Series power meters are compatible with the
8480, E-Series and new P-Series power sensors.
The P-Series power meters have a different sensor
input connector than the EPM and EPM-P Series
power meters, so it is necessary to use adapter
cables (part numbers N1917A/B/C). When using
the 8480 or E-Series sensors, refer to the Cable
Accessories section in this guide. For additional
information, refer to the Literature reference sec-
tion.
The standard P-Series power meters include:
Single-channel power meter, order N1911A
or dual-channel power meter, order N1912A
Input sensor connector(s) on the front panel
Reference calibrator (1 mW, 50 MHz) connector
on the front panel
Hardcopy English-language Installation Guide
CD-ROM, containing the English-language
and localized User’s Guides and the English-
language Programming Guide
Supplied accessories: power cord (plug matches
country destination requirements)
P-Series Wideband Power Sensors
The P-Series wideband power sensors are
designed specifically for operation with the
P-Series power meters for wide bandwidth power
and time measurements. These sensors are the
only Agilent power sensors that have their cable
hard-wired into the sensor. This provides better
wide bandwidth specifications compared to hav-
ing a removable cable. Refer to the Sensor Cable
Lengths section in this guide for part number
and cable length information.
The standard P-Series power sensors include:
Power sensor 50 MHz to 18 GHz, order N1921A
Power sensor 50 MHz to 40 GHz, order N1922A
English-language Operating and Service Manual
Compatibility
Power sensor compatibility
The P-Series power meters are compatible with all
current 8480, E-Series and P-Series power sensors.
Refer to the Accessories section, P-Series meter
cable adaptors N1917A/B and C.
Connector options for P-Series power meters
The following options are available on the P-Series
power meters.
1
Table 1. Connector options for P-Series power meters
Option Description
N1911A-003 Rear panel sensor and power reference
connectors (single channel)
N1912A-003 Rear panel sensor and power reference
connectors (dual channel)
1. The P-Series power meters are configured for either front panel connectors (both
sensor and power reference) or rear panel connectors. There are no options for
parallel front and rear panel sensor inputs.
Seitenansicht 1
1 2 3 4

Kommentare zu diesen Handbüchern

Keine Kommentare