high performance isotropic probes
to cover the 100 KHz to 6 GHz
frequency ranges
Two probes are available: from 100 KHz to 3 GHz and
from 700 MHz to 6 GHz. Both probes are made of three
orthogonal monopoles. The patented shape of each
monopole optimizes the functioning and isotropy of the
probe over the entire frequency range.
Mechanical characteristics 100 KHz - 3 GHz probe
Dimension (without cable) 406 mm
Weight 980 gr
RF cable length 2 m
Connector 3N
Protection IP 44
Conditions for use
(temperature, humidity) -10 to 50°c, 85 % humidity
Electrical characteristics 100 KHz - 3 GHz probe
Sensitivity at 900 MHz 1 mV/m
(Given for a spectrum analyzer
sensitivity of -90 dBm)
(Cable loss taken into account)
Max. E-fi eld/900 MHz 200 V/m
Isotropy at 900 MHz ± 1 dB
Isotropy at 1800 MHz ± 1,7 dB
General public - INSITE Free