Agilent Technologies InfiniiVision 7000 Series Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messen, Testen & Steuern Agilent Technologies InfiniiVision 7000 Series herunter. Agilent Technologies InfiniiVision 7000 Series Product data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Agilent Technologies
Infi niiVision 7000 Series Oscilloscopes
Data Sheet
Engineered for the best signal visibility
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Agilent Technologies

Agilent TechnologiesInfi niiVision 7000 Series OscilloscopesData SheetEngineered for the best signal visibility

Seite 2 - (source: Prima Data, 2007)

Evaluation kit (N2918A)The evaluation kit includes a variety of signals that demonstrate MegaZoom III technology with its fast deep memory, superior w

Seite 3

Probes and accessoriesAgilent offers a complete family of innovative passive and active probes for the InfiniiVision 7000 Series scopes helps you get

Seite 4

The 7000 Series scopes come with the most comprehensive connectivity tools in their class.LXI class CLAN eXtensions for Instrumentation (LXI) is a sta

Seite 5 - Other useful features

Agilent’s Infi niiVision lineup includes 5000, 6000 and 7000 Series oscilloscopes. These share a number of advanced hardware and software technology b

Seite 6

Agilent Infi niiVision 7000 Series oscilloscopes: Engineered for the best signal visibility12.1” large display makes it easier to view analog,digital a

Seite 7 - Measured update rates

Quickly pan and zoom for analysis with MegaZoom III’sinstant response and optimum resolution.Save screen images to a connected USB storage device.Stan

Seite 8 - Software applications

Performance characteristicsAcquisition: scope channels Sample rate MSO/DSO701xA: 2 GSa/s each channel MSO/DSO703xA: 2 GSa/sec each channel MSO/

Seite 9

Performance characteristics (continued)Vertical system: scope channelsScope channels MSO/DSO7xx2A: Ch 1 and 2 simultaneous acquisition MSO/DSO7xx4

Seite 10 - Soft carrying case (N2733A)

Performance characteristics (continued)Vertical system: scope channels (continued)ESD tolerance ±2 kVNoise, RMS, input shorted MSO/DSO701xA: 0.50% F

Seite 11 - Probes and accessories

Performance characteristics (continued)HorizontalRange MSO/DSO701xA: 2 nsec/div to 50 sec/div MSO/DSO703xA: 2 nsec/div to 50 sec/div MSO/DSO705

Seite 12 - Connectivity

Agilent has been the fastest growing oscilloscope supplier since 1997 (source: Prima Data, 2007). Wonder why? Agilent engineers developed the Infi ni

Seite 13

Performance characteristics (continued)Trigger system (continued)Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, FlexRay,

Seite 14

Performance characteristics (continued)Trigger system (continued)Nth edge burst Trigger on the Nth edge of a burst that occurs after an idle time tha

Seite 15

Performance characteristics (continued)Display systemDisplay 12.1-inch (255 mm x 184 mm) diagonal color TFT LCDThroughput of scope channels Up to 10

Seite 16 - Performance characteristics

Performance characteristics (continued)FFTPoints Fixed at 1000 pointsSource of FFT 1, 2, 1+2, 1-2, 1x2, MSO/DSO7xx4A: 3, 4, 3+4, 3-4, 3x4; where

Seite 17 - (continued)

Performance characteristics (continued)General characteristics (continued)Trigger out When Triggers is selected (delay ~17 ns) 0 to 5 V into hi

Seite 18

Ordering informationModel Bandwidth Sample rate Memory depth Scope channels Digital channelsDSO7012A 100 MHz 2 GSa/s 8 Mpts 2

Seite 19

Ordering information (continued)OptionsProduct Description DSO to MSO upgrade* N2741A for DSO701xA N2735A for DSO703xA N2

Seite 20

Related LiteraturePublication Title Publication Type Publication NumberAgilent Technologies Oscilloscope Family Brochure Brochure 5989-7650ENAgilent

Seite 21

Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications www.agilent.com

Seite 22

1. Biggest displayOscilloscopes are visual tools and large, high-resolution screens make the prod-uct better. Bigger displays have become increasingly

Seite 23

Your design has analog, digital and serial signals ... shouldn’t your scope?The Infi niiVision 7000 Series scope channels provide faster identifi cation

Seite 24

Other useful features High resolution mode. Offers up to 12 bits of vertical resolution in real-time, single-shot mode. This is accomplished by serial

Seite 25 - Ordering information

Why does a fast update rate matter? While bandwidth, sample rate and memory depth are key criteria for deciding which scope to purchase, an equally im

Seite 26

How update rate affects signal visibilityCapturing random and infrequent events on an oscilloscope is all about statistical probabilities. The key to

Seite 27 - Related Literature

Software applicationsI2C/SPI serial trigger and decode (N5423A or Option LSS on new scope purchases)This application displays real-time time-aligned d

Seite 28 - Remove all doubt

CAN/LIN triggering and decode (N5424A or Option AMS on new scope purchases)Trigger on and decode serially transmitted data based on CAN and LIN protoc

Kommentare zu diesen Handbüchern

Keine Kommentare