Agilent Technologies E6640A EXM Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Entwicklungssoftware Agilent Technologies E6640A EXM herunter. Agilent Technologies E6640A EXM Technical data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Test Set

Agilent TechnologiesSecurity Features and Document of VolatilityAgilent E6640AEXM Wireless Test Set

Seite 2 - Safety Notices

10 Products Covered by this Document

Seite 3 - Warranty

11Security Terms and Definitions4Security Terms and DefinitionsTerm DefinitionClearing As defined in Section 8-301a of DoD 5220.22-M, “National Indust

Seite 4

12 Security Terms and Definitions

Seite 5 - 1 Table of Contents

13Instrument Memory & Document of Volatility5 Instrument Memory & Document of VolatilityThis chapter summarizes all memory types in the instru

Seite 6 - Contents

14 Instrument Memory & Document of VolatilityMemory in the ControllerMemory in the ControllerThis section contains information on the memory compo

Seite 7 - Service Offices

15Instrument Memory & Document of VolatilityMemory in the Frequency ReferenceMemory in the Frequency ReferenceThis section contains information on

Seite 8

16 Instrument Memory & Document of VolatilityMemory in the TRXMemory in the TRXThis section contains information on the memory components availabl

Seite 9 - Document

17Instrument Memory & Document of VolatilityMemory in the TRX8. DRAM 4 GB DDR2Yes Yes Signal data captured WDIF Cycle power.8. DRAM 4 GB DDR2Yes Y

Seite 10

18 Instrument Memory & Document of VolatilityMemory in the TRX

Seite 11 - Definitions

19Memory Clearing, Sanitization and/or Removal Procedures6 Memory Clearing, Sanitization and/or Removal ProceduresThis section explains how to clear,

Seite 12

Notices© Agilent Technologies, Inc. 2014No part of this manual may be reproduced in any form or by any means (including electronic storage and retriev

Seite 13 - Document of Volatility

20 Memory Clearing, Sanitization and/or Removal ProceduresInstrument Sanitization ProceduresInstrument Sanitization ProceduresRemovable Hard Drive Dat

Seite 14 - Memory in the Controller

21Memory Clearing, Sanitization and/or Removal ProceduresInstrument Sanitization ProceduresFigure 6-1 Removing the hard drive1. Turn the PXIe chassis

Seite 15

22 Memory Clearing, Sanitization and/or Removal ProceduresOther MemoriesOther MemoriesOther memory devices in the E6640A are described in: • “Memory

Seite 16 - Memory in the TRX

23User and Remote Interface Security MeasuresSCPI/GPIB Control of Interfaces7 User and Remote Interface Security MeasuresThis chapter discusses option

Seite 17

24 User and Remote Interface Security MeasuresDetermining the Test Set’s Operating System• You can install standard third-party antivirus and spyware

Seite 18

25User and Remote Interface Security MeasuresUSB InterfacesIf you want to understand details of how this AutoPlay setting affects the Windows Registry

Seite 19 - Procedures

26 User and Remote Interface Security MeasuresUSB InterfacesFigure 7-1 Autorun Flag Definitions for NoDriveTypeAutoRun Registry entryAs shown in Figu

Seite 20 - Hard Drive Removal

27User and Remote Interface Security MeasuresUSB InterfacesFigure 7-2 Windows XP Run Dialogb. For Windows 7, click the Windows Start button at the bo

Seite 21

28 User and Remote Interface Security MeasuresUSB InterfacesMicrosoft AutoRun PatchNOTE The information in ths section applies only to Windows XP. If

Seite 22 - Other Memories

29User and Remote Interface Security MeasuresUSB Interfacesb. For Windows 7, click the Windows Start button, then select Shut down > Log off from t

Seite 23 - Security Measures

3WarrantyThis Agilent technologies instrument product is warranted against defects in material and workmanship for a period of one year from the date

Seite 24 - USB Interfaces

30 User and Remote Interface Security MeasuresUSB Interfaces

Seite 25

31Procedure for Declassifying a Faulty Instrument8 Procedure for Declassifying a Faulty InstrumentEven if the instrument is not able to power on, it m

Seite 26

32 Procedure for Declassifying a Faulty Instrument

Seite 27

33ReferencesA: References1. DoD 5220.22-M, “National Industrial Security Program Operating Manual (NISPOM)”United States Department of Defense. Revise

Seite 28 - Configuring USB for Read-only

This information is subject to change without notice.© Agilent Technologies, Inc. 2014Published in USA, January 2014E6630-90005Agilent TechnologiesRef

Seite 30

Contents 51 Table of Contents2. Contacting Agilent Sales and Service Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 32

7Contacting Agilent Sales and Service Offices2 Contacting Agilent Sales and Service OfficesAssistance with test and measurement needs, and information

Seite 33 - A: References

8 Contacting Agilent Sales and Service Offices

Seite 34 - Agilent Technologies

9Products Covered by this Document3 Products Covered by this DocumentThis document describes instrument memory types and security features. It provide

Kommentare zu diesen Handbüchern

Keine Kommentare